Log:
Assessments - 1, GPA: 3 ( )

Instruções de Operação Roland, Modelo SRV-2000

Fabricante : Roland
Arquivo Tamanho: 1.62 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


if you happen to do that by mistake, simply turn off the SRV-2000, then turn it on in a proper way. * Approximately once five years, battery replacement is required. Refer to page 33 for the details. 9 U Advanced Operation 1. CONNECTION Pre-stage Device M D! MIC >1 Device with IN OUT Device with MIDI IN MIDI OUT © Direct Reverb Balance Knob ’ THRU IN REMOTE SWITCH fcFFECl f ON/Of-F^ О CO \JL/ OUTPUT Б A (MONOS T 1 I i i i i (R) t T É © Input/Output Level Selector Switch i' (L) Post-stage Device DP-2 (Refer to page 29) © Input/Output Level Selector Switch Select either position depending on the input/ output level of the connected unit [Setting Examples] Keyboard.etc. HI + 4dBm: Roland Rack System Professional Audio Equipment jbl -20dBm: Electronic Musicai Instrument such as synthesizer. Consumer-type Audio Equipment, etc. * Both input and output levels are changed with this switch. Therefore even if you change the position of this switch, there is no volume difference, but it is important to select the appropriate position for delay effect with the least noise and distortion. 7 . 1 , OUTPUT INPUT 'ML 9 lïAt.ANCf ¡ - —n 'íAtN • 9 i 1 i - 20dBm ÍR)f yílí Keyboard Amplifier PA Mixer Audio Equipment Direct Reverb Balance Knob This can change the proportion of the direct and reverb sounds. Rotating this counterclockwise will increase the proportion of the direct sound, and clockwise wili increase the reverb sound. Usually, set it to V' position. Pre amplifier OUTPUT Guitar Amplifier D Guitar Amplifier Connecting a guitar directly to the SRV-2000 wil! be no good, as its input impedance is not high enough. 10 © Bypass Indicator © Level Indicator Here, the glowing indicator shows either the attenuated signal level or the reverb output signal level. The signal higher than the other is detected and the corresponding indicator lights up. © Input Attenuator Set this knob to the appropriate position where the Input Level Indicator "+6dB" lights up at its peak. When you cannot manage to do it with this knob, change the position of the Input/Output Level Selector Switch©. {See page 10.) O Bypass Switch When this switch is turned on (when the Bypass Indicator glows), the signal fed into the Input Jack 0will be perfectly passed through and sent out from the Output Jack © or ®. * If the Bypass switch is turned on or off during performance (while the signal is passing through), noise will be noticed, but there is nothing to worry about. © Bypass Indicator * When the SRV-2000 is turned off, this indicator does not light up. * When the Input Attenuator is set to "OdB", the output level is equal to the input level (= Gain is UNITY). Even if it is turned fully counterclockwise, the level wil! not be zero. About Shift Buttons Number increases The Shift Buttons 1 to 6 KD and to©) serve to change the numbers (parameter values) in the Display Windows 1 to 6 {© to ®). Pressing the upper side of the button " ^ " will advance a number and " « " side wil! back up a number. Also, pressing one side while holding the other side down will quicken the change. 11 2. CONTROL PANEL The SRV-2000 has two basic operation modes; the Reverb mode and Non-linear mode. When in the Reverb mode, the SRV-2000 operates as a usual reverb machine, and in the Non-linear mode, the reverb sound is cut according to the set gate time. Also, each operation mode allows separate setting of the parametric equalizer. (See page 19.) © Copy Button (Refer to Page 27 ) © Write Button (Referto page 25) ©MIDI Display Button © Operation Mode Indicator © Equalizer Display Indicator © Room Simulate Button (Refer to page 16 © Equalizer Display Button © Operation Mode Selector Button This lights when in the Reverb mode. This lights when in the Non-Linear mode. This flashes when in the Equalizer Display mode. This flashes when in the MIDI Display mode. © Operation Mode Indicator This indicates which operation mode is currently selected. In the Reverb mode, glowing i reverb i is shown, and in the Non-Hnear mode, ¡non lnr; . Display Mode Indicator When l eq j is flashing here (= Equalizer Display mode), the Display Windows show the values of equalizer's parameters. When I......mo,, j is flashing, the Windows show the settings of MIDI such as MIDI Channel number. Program Change number, etc. When both l eq i and i midi i are dark (= usual Display mode), the parameter values of the Reverb or Non-linear will be shown in the Windows depending on the Operation mode currenly in use. 0 Operation Mode Selector Button This button selects either of the Operation mode, Reverb or Non-linear. Each time the button is pushed, the mode changes from one to the other. © Equalizer Display Button Pushing this button will turn the SRV-2000 from the usual Display mode to the Equalizer Display mode. And pushing it again will return to the usual Display mode. 0 MIDI Display Button Pushing this ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias