Log:
Assessments - 6, GPA: 4.3 ( )

Instruções de Operação Beko, Modelo M 5604 CTX

Fabricante : Beko
Arquivo Tamanho: 1.16 mb
Arquivo Nome :
Língua de Ensino: ruen
Ir para baixar



Facilidade de uso


»■Assembly the terminal block cover to its place. The mains cable must pass through the coble clamp (2). *■ Fix the supply cable to main body with two screw via cable tightener (2). Your oven is suitable for sing/e and three phase connection. •"7/ie mains cable should be routed away from the appliance and in particular ventilation slots, the vent outlet and should not be obstructed when pushed in to position between the appliance and the wall and/or cabinet. ■f: T: >0 J--U >o >0 ;>o 3*0 AC 220№C№40V 3-0 3-0 >o >o >0 3*0 3N AC aeoMOQMi 5 v 3-0 3-0 3-0 :>c: >0 3iK3 2N AC S0OÎ4OCV415 V Schema II Connection Type Monophase Three phase with Neu fra/ Two phase with Neutral Voltage 220/230/ 240 V 380/400/415 V 380/400/415 V Supply cord type (max 2m long) 3x2,5 mm2 H05 V V-F 5x2,5 mm2 H05 V V-F 4x2,5 mm2 H05 V V-F Schema I Adjacent side walls above the appliance must not be nearer to the cooker than 150 mm and should be of heat resistant material. Leave at least 750 mm clearance above the hotplates. The appliance should be located on a level surface. The two front feet can be adjusted as required. To ensure that your appliance is standing level adjust the two front feet by turning clockwise or counterclockwise until the product is in firm contact with the floor. 4 Installation of gas tookers »-Before your appliance is connected to the gas supply, cfiec/r the ensure that the gas category and pressure specifications shown in the data plate corresponds with your gas supply. If necessary call authorized service for adjusting to gas category. »■This appliance shall be installed in accordance with the regulations in force and only used in a well ventilated space. Read the instructions before installing or using this appliances. In the interest of safety this appliances must be installed and/or serviced by a competent person as stated in the gas safety regulations current editions. *■ Please refer to the data plate for details about gas supply and pressures. The appliance must not fee installed in a room without a window or other controllable opening. If is installed in a room without a door which opens directly to tohe outside, a permanent opening is required. The air circulation should be 2 m3/h per kW of burners. Connection of Iho gas ho*« to thm ovmn Convenient position is selected by Interchanging the hose nozzle and plug according to the location of the main gas inlet valve. If you make a connection with a flexible metal hose , locate a seal between the moin gas pipe. The Inner diameter of the flexible hose, which the butane hose nozzle is connected, should be 6mm for the house-type gas tubes. The inner diameter of the flexible hose, which the natural hose nozzle is connected, should be 15mm. The hose should lightly be fitted to the hose nozzle by squeezing with a clamp. The plastic hose end is soaked in hot wafer for one minute to soften and inserted fully into the hose nozzle. The clamp is fastened securely by a screw driver. The other end of the hose is connected to the gas valve with the same operation. The hose should be replaced before its last expiry date. plug Hose nozzle Cautiont Make the oven connection to the gas inlet valve, the hose length must be short and be sure that there is no leakage. The hose used should not be longer than 125 cm for safety. № Connection of the доя hose to the even Convenient pos/f/on is selected by interchanging the hose nozzle and plug according to the location of the main gas inlet valve. The plastic hose end is soaked in hot water for one minute to soften and inserted fully into the hose nozzle. The clamp is fastened securely by a screw driver. The other end of the hose is connected to the gas valve with the same operation. Gas leakage tontrol During control, be sure that the control knobs are closed and the gas inlet valve is open. Apply soap bubbles to the connections for leakage control. In case leakage exists, buble will appear. In such case, check the gas connection immediately. Do not control gas leaks by using fire. Cautionl Never use lighter or match flame, for controlling the gas lackage. Hose nozzle and elbow types for Natural gas and Butane/propane 5 Part 3s Technical specifications 1. Burners plate 2. Control panel 3. Front door 4. Handle 5. Storage compartment 6. Tray 7. Grill shelf S. Integral air oven There may also be plate location other than the ways shown in the figures. The fast radian, extended and dual plates bum with that brillant light when they are first ON. A rapid heating solid plates are as denoted by a red spot in the centre of the plate. The voltage, frequency and maximum powers shown in the data plate . Conventional cookers Multi-function cookers Fan assisted cookers GriH waitaae 800/1500 800/}500 800/1500 Oven wattpQQ 1900 W 1900 W 1900 VV Tyibo WQttOQG - 1800 W Turbo motor wallaas - JB W/2800 rpm 38 W/2800 rpm Lamo 25 W 25 W 25 W External dime...

Este manual também é adequado para os modelos :
Placa - ET 5604 GIX (1.16 mb)
Placa - M 5614 CMX (1.16 mb)
Placa - M 5604 GIMX (1.16 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias