Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação KitchenAid, Modelo KBZU242TSS

Fabricante : KitchenAid
Arquivo Tamanho: 529.86 kb
Arquivo Nome : fb421466-23d6-45e0-b66a-3bca4337a1de.pdf
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


Parts Supplied ¦ Convertible regulator set for 4" WCP Natural gas. ¦ Single-prong plug/5,000 mAmp transformer assembly Location Requirements Select a location that provides minimum exposure to wind and traffic paths. The location should be away from strong draft areas. Do not obstruct flow of combustion and ventilation air. Clearance to combustible construction for built-in outdoor side burners: ¦ A minimum of 24" (58 cm) must be maintained between the sides and back and any combustible construction. ¦ A 24" (58 cm) minimum clearance must also be maintained below the cooking surface and any combustible construction. Ignition A grounded, 3 prong outlet located to the left of the side burner is required. See “Electrical Requirements” section. Product Dimensions Style 1 -Front to Back Built-In Dual Side Burners A B C D E F H G A. 13" (33 cm) E. 25..." (64.5 cm) B. 10..." (27 cm) F. Manifold pipe C. 17" (43.2 cm) G. 4..." (11.1 cm) D. 26..." (67 cm) H. 22..." (57.8 cm) Style 2 - Side by Side Built-In Dual Side Burners A B C D E F A. 24" (61 cm) B. 10..." (27 cm) C. 28" (71.1 cm) D. 20..." (52.1 cm) H E. 19..." (49.5 cm) F. Manifold pipe G. 4..." (11.1 cm) H. 17" (43.2 cm) G Built-In Outdoor Side Burner Enclosure The enclosure for the built-in outdoor side burner is to be a minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x 14" (35.6 cm) wide for front to back model and 11" (28.0 cm) high x 17" (43.2 cm) deep x 25" (63.5 cm) wide for side by side model. Cabinet Dimensions Enclosure and clearance dimensions that are shown must be used. Given dimensions provide required clearances. Counter or support surfaces must be level. The installation of this side burner must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2. Copies of the standards listed may be obtained from: CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575 NOTE: The outdoor side burner drops into the enclosure opening and is supported by its side flanges. No bottom support is needed. A B C D E F G H A. 12" (30.5 cm) minimum to side D. 2..." (5.7 cm) burner or any accessory E. 6..." (15.7 cm) B. 13..." (34.3 cm) on front to back F. Gas line location at rear of models, 24..." (62.2 cm) on side by side burner side models G. 10..." (27.3 cm) C. 22..." (57.5 cm) on front to back H. 35..." (90.2 cm) models, 16..." (42.9 cm) on side by side models Built-in Outdoor Side Burner Enclosure Ventilation for LP Gas: An enclosure for an LP gas fuel tank is to be ventilated by openings at both the top and lower levels of the enclosure. If converting to LP gas these vents are to be in the enclosure: An enclosure for use with an LP gas fuel tank for built-in installation is to have at least one ventilation opening on an exposed exterior side located within 5" (12.7 cm) of the top and is to be a minimum of 20 in.2 (129.0 cm2). One ventilation opening within 1" (2.5 cm) of the bottom of the enclosure and the bottom opening is to be a minimum of 10 in.2 (64.5 cm2). All vent openings are to be unobstructed. Every opening is to be a minimum of ..." (0.32 cm) wide. 10 in.2 (64.5 cm2) min. ventilation both sides 5" (12.7 cm) max. 5" (12.7 cm) max. 20 in.2 (129.0 cm2) min. ventilation both sides 1" (2.5 cm) max. Electrical Requirements WARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sure whether the side burner is properly grounded. A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is required. It is recommended that a separate circuit servicing only this side burner be provided. The model/serial number rating plate is located on the right-hand side panel. See the following illustration. A A. Model/serial number plate Recommended Ground Method The outdoor side burner, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code, CSA C22.1. Copies of the standards listed above may be obtained from: CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575 National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269 A B C A. 3 prong ground plug B. 3-prong polarized type outdoor GFI outlet C. Ground prong Gas Supply Requirements WARNING Explosion Hazard Use a new CSA International approved “outdoor” gas supply line. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 11” ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias