Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação CDA, Modelo 4Q4

Fabricante : CDA
Arquivo Tamanho: 1.04 mb
Arquivo Nome : aec24ec3-84b4-4209-9804-939c759eef46.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


11 and 12). They shall be level and must not rotate. Failure to do so can cause serious problems. . The pan supports shall be correctly positioned as indicated in fig. 13. The pan supports shall be level and must not rotate. Models with triple-ring burner: be sure not to fit the triple-ring burner pan support on the auxiliary, semirapid or rapid burners. The triple-ring burner pan support IS ONLY to be used on the triple-ring burner. Figure 11 Figure 12 Figure 13 F C CORRECT POSITIONING OF THE AUXILIARY, SEMIRAPID AND RAPID BURNERS Flame failure probe "T" Ignitor "S" 17 Figure 14 A B Figure 15 Figure 16 Figure 17 Flame failure probe "T" Ignitor "S" The triple ring burner must be correctly positioned (see fig. 14); the burner ribs must be fitted in their housing as shown by the arrow. The burner correctly positioned must not rotate (fig. 15). Then position the cap “A” and the ring “B” (figs. 15 - 16). They shall be level. . The pan support shall be correctly positioned as indicated in fig. 17. The pan support shall be level and must not rotate. Be sure not to fit the auxiliary, semirapid or rapid burner pan support on the triple-ring burner. The auxiliary, semirapid or rapid burner pan support IS ONLY to be used on the auxiliary, semirapid or rapid burners. MODELS WITH TRIPLE RING BURNER - CORRECT POSITIONING OF THE TRIPLE RING BURNER Tips for installation Location Location . The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but not in a room or space containing a bath or a shower. . The appliance must not be installed in a bed-sitting room of less than 20 m3. . The appliance is designed and approved for domestic use only and should not be installed in a commercial, semi commercial or communal environment. . Your product will not be guaranteed if installed in any of the above environments and could affect any third party or public liability insurances you may have. . This hob should only be installed by a qualified installer. Failure to observe this rule leads to cancellation of the guarantee. . The appliance must be installed correctly, in compliance with the regulations in force and following the manufacturer's instructions. . Any repair or maintenance must be performed with the appliance switched off. . These hobs are designed to be fitted into 600 mm deep kitchen units. . These appliances have been designed and manufactured to be fitted into heat-resistant units. . The walls of the units must be capable of resisting temperatures of 75 °C above room temperature. . We would point out that the adhesive which bonds the plastic laminate to the furniture must withstand temperatures not less than 150 °C to avoid elamination. . Avoid installation near inflammable materials (e.g. curtains). TECHNICAL INFORMATION FOR THE INSTALLER In order to install the cooktop into the kitchen fixture, a hole with the dimensions shown in fig. 19 has to be made, bearing in mind the following: . Within the unit, between the bottom of the cooktop and the upper surface of a shelf there must be a clearance of at least 30 mm. It is absolutely essential that you place a separator between the base of the cooktop and the built-in unit or the oven; . The cooktop must be kept no less than 200 mm away from any side wall (fig. 18). . There must be a distance of at least 60 mm between the back side of the cut-out and the back of the countertop. . There must be a distance of at least 650 mm between the hob and any wall cupboard or extractor hood positioned immediately above (see fig. 18). . If the hob is installed over a built-in oven, the built-in oven shall be provided with cooling fan. The two appliances shall be connected to the gas/electric supply with independent connections. Figure 18 20 500 mm200 mm min 650 mm450 mm Figure 19 480 60(2) 560 585510 54 (1) 680 715510 480 60(2) 54 (1) 840 869 480 510 60(2) 54 (1) HVG 65 -4Q HVG 75 HVG 95 (1): 54 mm from top of countertop (2): at least 60 mm between the back side of the cut-out and the back of the countertop. 4 INSTALLING THE Figure 20 SEPARATOR BELOW THE BASE OF THE COOKTOP It is recommended that a 30 mm clearance be left between to base of the cooktop and the separator. The separator shall be heat resistant, made of low thermal conductivity material and shall be removable with the use of a tool for installation and service. 21 30 mmSpace for connections Clearance Separator FASTENING THE COOKTOP Each cooktop is provided with an installation kit including brackets and screws for fastening the cooktop to benches from 30 to 40 mm thick.The kit includes two "F" type brackets (for the front of the cooktop), two "R" type brackets (for the rear of the cook- top) and four self-threading screws "S" (figs. 21, 22a and 22b). . Cut the unit according to the dimensions in fig. 19. . Turn the hob upside down and rest the glass side on a soft surface. . Spread the seal "G" around the edge of the hob (fig. 21). . Fasten the brackets "F" and "R" to the appropriate socket hol...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias