Instruções de Operação Weil-McLain, Modelo CG50

Fabricante : Weil-McLain
Arquivo Tamanho: 475.57 kb
Arquivo Nome : a5ba57f0-b0d3-451a-a2ab-3006110b0643.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Standard motor voltage is 120/60/1 for CG10, CG25 , and 230/60/1 for CG50. 2. Direct Spark Ignition is standard on all models. 3. CG10 models are available only as OO (On-Off operation) or LFS (Low fire start, high fire run. Single position air, adjustable opening gas valve). 4. CG25 and CG50 are available as: LHL Low-high-low-off operation. Two position air controlled by linkageless damper actuator, fixed damper pre-purge. • Must be wired with boiler temperature or pressure control switch or operation will be low-high-off. • MOD – On-off operation with proven low fire start and full modulating firing conditions with combustion air control. • Modulation control drives combustion air damper and fuel metering valve in response to boiler demand. Fixed damper pre-purge for RM 7897C. • Open damper pre-purge for RM7840L. 5. Burner capacities listed for elevations up to 2,000 feet. For higher elevations, consult local Weil-McLain distributor/ agent or sales office. 6. Gas ratings based on natural gas with heating value of 1,000 btu per cubic foot and specific gravity of 0.60. 7. Boiler-burner unit to be adjusted to achieve +0.10 inches W.C. pressure at flue collar, resulting in positive pressure in firebox as listed. 8. Minimum gas pressures listed are subject to variations due to job conditions. Gas burners for other gas pressures are available. Consult local Weil-McLain distributor/agent or sales office. 9. Gas manifold pressures shown are for initial start-up. Final pressure should be determined after checking actual gas flow and combustion readings. 10. Combustion Controls: a. RM7897 flame safeguard control uses ultraviolet electronic flame detector to monitor gas burner flame, and provides pre-purge programming. “C” models provide 10 second main flame establishing period. b. RM7840L flame safeguard control monitors the gas burner flame, provides pre-purge and post-purge programming, provides switching necessary to allow firing rate motor to be driven to both low fire start and high fire positions, prevents start-up if preignition interlock circuit or running interlock circuit does not “prove”, system will lock out on safety. Ultraviolet sensitive electronic flame detector is standard. 11. Burners listed by Underwriters Laboratories, Inc., Canadian Gas Association, state of Connecticut, Fire Marshal state of Massachusetts, city of New York MEA, and others. 12. Special controls can be provided to meet other code requirements not listed. Consult your local Weil-McLain distributor/ agent or sales office. Part No. 550-142-027/0508 Weil-McLain 88 Water and Steam Boilers — Series 2 — For Gas, Light Oil, & Gas/Light Oil-Fired Burners Burner dimensions Figure 2 Beckett model CG10 Figure 3 Beckett models CG25 and CG50 Burner Dimensions, In Inches Model Number A B C D E F G H I J K L Pipe Thread Overall Square Bolt Maximum Centerline Tube Overall Burner Centerline Centerline Centerline Insertion Width Flange Width & Height Circle Tube O.D. To End Of Manifold ...

Este manual também é adequado para os modelos :
Greeley - CG10 (475.57 kb)
Greeley - CG25 (475.57 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias