Fabricante : Broil-Mate
Arquivo Tamanho: 2.22 mb
Arquivo Nome : OM_LPNG.pdf
|
Facilidade de uso
GAS CYLINDER.........................................3 OPD EQUIPPED CYLINDER.............................4 HOSE & REGULATOR......................................4 LEAK TESTING.................................................5 VENTURI TUBES..............................................5 LIGHTING..........................................................6 OPERATION......................................................7 COOKING TECHNIQUES..................................7 MAINTENANCE...............................................10 TROUBLE SHOOTING....................................11 WARRANTY....................................................12 READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR GAS BARBECUE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE 1-800-265-2150 info@omcbbq.com 10094-LP REV F 01/08 Please record your model and serial number here. Model number Serial number Date of purchase SAFETY INSTALLATION Your new OMC gas grill is a safe, convenient appliance when assembled and used properly. However, as with all gas-fired products, certain safeguards must be observed. Failure to follow these safeguards may result in damage or injury. If you have questions concerning assembly or operation, consult your dealer, gas appliance serviceman, your gas company or our direct customer service line at 800-265-2150. FOR YOUR SAFETY • If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. Open lid. 4. If odour continues, keep away from the appliance and immediately call your gas supplier or your fire department. DO NOT store or use gasoline, or other flammable vapours and liquids in the vicinity of this or any other appliance. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. CAUTION • FOR OUTDOOR USE ONLY. • IF STORED INDOORS, DETACH AND LEAVE CYLINDER OUTDOORS. • THIS APPLIANCE MUST NOT BE OPERATED UNATTENDED. • SPECIAL CARE MUST BE TAKEN TO KEEP SMALL CHILDREN AWAY FROM HEATED SURFACES. Use caution when handling or transporting this product. Metal edges can present a hazard. Use appropriate gloves when lifting or handling. Before lifting, remove side shelves and grids and grates. ELECTRICAL CAUTION 1. If any accessory is used on this appliance that requires an external electrical power source, the accessory when installed must be electrically grounded in accordance with local codes. In the absence of local codes, the following standards apply: (U.S.A.) ANSI/NFPA No. 70-Latest Edition and (CANADA) CSA C22.1 Canadian Electrical Code 2. Do not cut or remove the grounding prong from the plug. 3. Keep the electrical supply cord and fuel supply hose away from any heated surface. WARNING Fuels used in gas or oil-fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. “This warning is issued pursuant to California Health and Safety Code Sec. 25249.6” 1. In Canada, this appliance must be installed in accordance with the local code and the relevant CSA standards: CSA-B149.1 Natural Gas and Propane installation Code In the U.S.A., this appliance must be installed in accordance with the local code and the relevant national code. ANSI Z223.1/NFPA 54 - Latest Edition National Fuel Gas Code and Latest Local Codes where Applicable 2. The appliance must be located away from combustible surfaces by at least 76cm/30” from each side, and 76cm/30” from the rear. 76cm / 30” 76cm / 30” 3. Do not operate this appliance under any overhead roof construction or foliage. 4. This appliance is for OUTDOOR USE ONLY, DO NOT operate in garage, shed, balcony or other such enclosed areas. 5. DO NOT restrict the flow of air to the appliance. 6. Keep the area surrounding the appliance free of combustible materials, gasoline, and all flammable liquids and vapours. 7. This appliance is not intended to be installed in, or on, recreational vehicles and/or boats. LP GAS CYLINDER PLACEMENT 8. LP gas cylinders must be installed according to assembly instructions using retainer provided. Do not store a spare cylinder under or near this appliance. LP GAS CYLINDER QCC®-1 QUICK CLOSING COUPLING All models are designed to be used with an LP gas cylinder equipped with the QCC®-1 Quick Closing Coupling system. The QCC®-1 system incorporates new safety features required by the American National Standards Institute (ANSI) and the Canadian Standards Steering Committee. • Gas will not flow until a positive connection has been made. • A thermal element will shut off the flow of gas between 240° and 300° F. • When activated, a Flow Limiting Device will limit the flow of gas to 10 cubic feet per hour. NIPPLE WITH FLOW SHUT OFF LIMITING DEVICE VALVE HEAT SENSITIVE CYLINDER HAND WHEEL REGULATOR CHECK VALVE The LP Gas Cylinder is not included with the Gas Grill. Be sure to purchase one with the QCC® valve. This valve is recognized by the external threads on the inl...
Este manual também é adequado para os modelos :Greeley - 115994 LP (2.22 mb)