Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Honeywell, Modelo 25326-016

Fabricante : Honeywell
Arquivo Tamanho: 219.08 kb
Arquivo Nome : C2-025_sideburner_instruction.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


2. Extinguish any flame. 3. Open lid. 4. If odor continues, immediately call your gas supplier or fire department. INSTALLER: Please leave these instructions with the consumer. CONSUMER: Retain for future reference. BRICK OPENING: 8 3/4" x 14 1/4" x 4" deep. Side shelves and connector kits for mounting side burners on portable carts or in countertop enclosures are packaged separately. SIDEBURNER SHELF MODELS #25326-016 & #25336-016 DROP-IN MODELS #3275 & #3280 INSTALLATION AND OPERATING INSTRUCTIONS FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. This manual may not be copied, photocopied, reproduced, translated, or published in any electronic or machine-readable form in whole or in part without prior written approval of Robert H. Peterson Co. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult qualified, professional installer, service agency or the gas supplier. We reserve the right to amend product specifications without prior notice. Certified to ANSI: Z21.58 Robert H. Peterson Co. • 14724 East Proctor Avenue, • City of Industry, CA 91746 REV A1 022305 No. L-C2-02505 1 2 SIDEBURNER PARTS LIST Your Fire Magic Sideburner is designed to complement your Fire Magic Barbecue. It provides a convenient, efficient cooking surface for side dishes that require bottom heat only. TOOLS REQUIRED: A pair of wrenches, pliers or vice grips for the gas connection. CODE AND SUPPLY REQUIREMENTS: This burner must be installed in accordance with local codes and ordinances or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1. This appliance and its individual shutoff valve must be disconnected from the gas supply piping system when testing the system at pressures in excess of 1/2 psig. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply system at pressures up to and including 1/2 psig. WHERE TO INSTALL YOUR SIDEBURNER Fire Magic Sideburners are designed for outdoor use only. WARNING: Sideburners must be installed in masonry or other type of fireproof enclosure. The unit is not insulated and therefore must be installed with 18" of side and back clearance from unprotected combustible materials such as wood, plastic, or stucco with wood framing. Do not install under overhead unprotected flammable construction. A 4" clearance to any back wall is required to open the lid properly. This is a drop-in type unit. The unit must be removable for gas hookup, servicing and burner adjustment. PROPER VENTILATION: Proper ventilation of your sideburner must be maintained to ensure proper performance. Do not operate with lid closed. VENTILATION OF ENCLOSURES When using propane gas, take EXTREME CAUTION to ensure ample ventilation of gas vapor. Propane vapor is invisible and heavier than air. A DANGEROUS EXPLOSION could occur, resulting in SERIOUS INJURY, OR LOSS OF LIFE if propane gas is allowed to accumulate and then ignite. PREPARING FOR INSTALLATION OF YOUR FIRE MAGIC SIDE BURNER 1. 3275-06 Handle assembly 2. 3275-04 Lid, porcelain OR 3280-04 Lid, S.S. 3. 3275-26 Lid stop (2) 4. 3275-10 Burner grid 5. 3005 Valve, w/o knob 6. 3020 Knob 7. 3275-39 Valve manifold assembly 8. 3275-35 Gas connector tube 9. 3275-32 Side burner assembly, complete Comprising of: 9A Orifice housing 9B Ignitor electrode 9C Venturi tube 9D Lock nut 9E Burner base 9F Burner cap 10. 3001-49-1 Burner orifice, nat gas #49 OR 3001-56-1 Propane gas #56 11. 3199-32 Ignitor spark generator Item Part Description(Qty.) No. No. Only one propane gas cylinder may be located in an enclosure. Extra or spare cylinders must be stored outdoors out of the reach of children and outside of any building, garage or other enclosed area. READ AND FOLLOW ALL WARNINGS PROVIDED WITH PROPANE GAS CYLINDERS. Never locate a cylinder under or near the barbecue unless sufficient ventilation and shielding is provided to prevent any heating of the cylinder, regulator and rubber hose. Propane Cylinder Enclosures To prevent invisible combustible gas from accumulating in your cylinder enclosure, you must provide adequate ventilation. This is accomplished by EITHER of the following methods. One side of the gas cylinder enclosure can be left completely open to the outside OR by providing four (4) ventilation openings. Two openings are to be at the cylinder valve level (approx.16” above the floor) and on opposite walls of the enclosure. Two more openings must be at the floor level on opposite sides of the enclosure. The floor level openings must start at the floor and shall extend no higher than 5” above the floor. Each opening must have a minimum of 10 square inches (64.5 cm2) of free area. To achieve the proper ventilation, you may drill a serie...

Este manual também é adequado para os modelos :
Greeley - 25326-016 (219.08 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias