Log:
Assessments - 3, GPA: 5 ( )

Instruções de Operação Apollo, Modelo SWING GATE OPERATOR 1600

Fabricante : Apollo
Arquivo Tamanho: 1.89 mb
Arquivo Nome : Apollo_1500-1600_Actuator_Swing_Gate_Opener_Manual.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Use mounting hardware capable of supporting the weight of the control box with the battery installed. Mounting holes are not provided since mounting surfaces will vary. STEP 4 Connecting the Actuator (s) Set battery inside of control box with terminals toward the front (Do not use any battery with side terminals). Connect actuator cable to the “MASTER” connector on the control board. If a 1600 is being installed and conduit is being used under the drive (recommended), cut the slave (opposite side where control box is mounted) actuator cable about 12” from the white connector. Run the remaining cable across the drive through conduit and up through the control box. Cutoff any excess cable and splice the short piece back to the cable. Connect to the “SLAVE” connector on the control board. Connect the RED power wire (s) to the battery positive ( + ) and the BLACK power wire (s) to the battery negative ( - ) 1/2” x 3 1/2” Hex Bolt 1/2” Washer 1/2” Lock Nut Do not over tighten nut Actuator InstallationSTEP 2 8 STEP 6 Limit Switch Adjustment To Retract More Turn Retract Limit Screw Clockwise To Retract Less Turn Retract Limit Screw Counter- Clockwise To Extend More Turn Extend Limit Screw Counter- Clockwise To Extend Less Turn Extend Limit Screw Clockwise Remove limit switch end capsCycle the operator and adjust limits as required. If the operator opens automatically after closing, extend less until gate remains closed. Do not retract the extension tube too far or the retract limit switch will not be activated. (You can depress the Limit Switch Test button on the 833/834 to see when the actuator has reached it’s limit) 1650 Adjustments As you open and close the gates, you will notice that the slave side moves 2-3 seconds slower than the master. Tip: By welding stop tabs on the top and bottom of the master side, the two gates may now be adjusted so the slave gate will close against the stop tabs of the master gate and create enough tension to prevent gates from moving back and forth. STEP 5 GATE BRACKET INSTALLATION Activate push button on the side of the control box and extend the actuator until it stops (PULL TO OPEN only, leave actuator retracted for PUSH TO OPEN). WARNING: Do not let extension tube rotate as it extends. Do not insert fingers or tools in the hole at the end of the extension tube Align the hole in the end of the actuator extension tube with the holes in the gate bracket and locate gate bracket mounting position with the gate in the closed position. Weld or bolt the gate bracket to the gate using 3/8” bolts, lock washers, and nuts. Tip: Tack weld or C clamp at first if uncertain about location. Run the unit through a complete cycle to insure proper operation then mount permanently . Bolt the actuator to the gate bracket as shown. Bracket should attach 52” - 54” from the center of the hinge. 1/2” x 3” Bolt 1/2” Lock Nut 1/2” Washer (2 places) Extend Limit Screw Retract Limit Screw STEP 6 Limit Switch Adjustment To Retract More Turn Retract Limit Screw Clockwise To Retract Less Turn Retract Limit Screw Counter- Clockwise To Extend More Turn Extend Limit Screw Counter- Clockwise To Extend Less Turn Extend Limit Screw Clockwise Remove limit switch end capsCycle the operator and adjust limits as required. If the operator opens automatically after closing, extend less until gate remains closed. Do not retract the extension tube too far or the retract limit switch will not be activated. (You can depress the Limit Switch Test button on the 833/834 to see when the actuator has reached it’s limit) 1650 Adjustments As you open and close the gates, you will notice that the slave side moves 2-3 seconds slower than the master. Tip: By welding stop tabs on the top and bottom of the master side, the two gates may now be adjusted so the slave gate will close against the stop tabs of the master gate and create enough tension to prevent gates from moving back and forth. STEP 5 GATE BRACKET INSTALLATION Activate push button on the side of the control box and extend the actuator until it stops (PULL TO OPEN only, leave actuator retracted for PUSH TO OPEN). WARNING: Do not let extension tube rotate as it extends. Do not insert fingers or tools in the hole at the end of the extension tube Align the hole in the end of the actuator extension tube with the holes in the gate bracket and locate gate bracket mounting position with the gate in the closed position. Weld or bolt the gate bracket to the gate using 3/8” bolts, lock washers, and nuts. Tip: Tack weld or C clamp at first if uncertain about location. Run the unit through a complete cycle to insure proper operation then mount permanently . Bolt the actuator to the gate bracket as shown. Bracket should attach 52” - 54” from the center of the hinge. 1/2” x 3” Bolt 1/2” Lock Nut 1/2” Washer (2 places) Extend Limit Screw Retract Limit Screw 9 635/636 CONTROL BOARD CONNECTIONS 8 6 4 2 7 5 3 1 8 Pin White Connector (two on 636 Master & Slave) 1 ORANGE - Open Limit Input (Nor...

Este manual também é adequado para os modelos :
Portão automático - SWING GATE OPERATOR 1500 (1.89 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias