Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Genie, Modelo 2020L Series

Fabricante : Genie
Arquivo Tamanho: 1.78 mb
Arquivo Nome : 603a9722-7f9a-4231-a4c6-a5a62ff4b0f0.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


B Install Lens into slots in Motor Cover. • Insert Bottom hinges into slots provided in metal front cover of Power Head. • Flip Lens up and fasten with molded latches on lens. Ins tallation of Lens and Bulb Figure 14 Install Lens and Light bulb Transmitter Compliance Statement WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 1 READ AND FOLLOW ALL INSTRUCTIONS. 2 Never let children operate or play with the Door Controls. Keep the Remote Control away from children. 3 Always keep the moving door in sight and away from people and objects until the door is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4 NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. 5 Test Opener monthly. The door MUST reverse on contact with a 1-1/2” high object (or a 2” x 4” board laid flat) at the center of the doorway on the floor. After adjusting either the Force or the Limit of travel, retest the Door Opener. Failure to adjust the Opener properly may cause severe injury or death. 6 When possible use the Emergency Release only when the door is closed. Use caution when using this Release with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death. 7 KEEP GARAGE DOORS PROPERLY BALANCED. See Owner’s Manual. An improperly balanced door increases the risk of severe injury or death. Have a Genie Factory Authorized Dealer make repairs to cables, spring assemblies, and other hardware. 8 SAVE THESE INSTRUCTIONS. Important Safety Instructions Notes SCheDuleD maiNteNaNCe A Monthly: • Door springs and door hardware: – Oil door roller, bearings, and hinges using silicone lubricant or light oil WARNING Do not operate door automatically or manually if springs are broken Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE • Balance Door – Close door – Release Carriage Assembly from Rail Assembly by pulling down on Emergency Release Knob – Raise door manually 3’- 4’ and verify that door stays at that position See Check Step 2 on page 4 NOTE When the door is 3’ - 4’ above the ground, the door should stay open Slight movement is acceptable If the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. – Reattach Carriage Assembly to Rail Assembly: a . Pull the Emergency Release Knob toward Power Head b Close door • Contact Reverse Test. – Perform Adjustment Step 2 on page 8 WARNING If the door fails to reverse on contact with the board, adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 9 If the Opener still fails, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE FCC AND IC CERTIFIED All devices comply with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation B As Needed: • Replace Light Bulb TRoubleShootiNG GuiDe Safe-T-Beam® System Self-Diagnostic Troubleshooting Source (Red LED) Sensor (Green LED) Possible Problem Solution ON ON Normal operation None required OFF OFF • Power Head not powered • Wiring from Power Head bad • Check breakers, fuses, plugs • Check wiring for obvious shorts OFF ON • Wiring to Source missing or bad • Power has been interrupted • Check wiring • Remove power and reapply 2 BLINKS, Pause (Repeat) ON • Beam not aligned • Beam obstructed • Sensor defective • Check Source, Sensor alignment • Check for obstruction • Contact Customer Service 2 BLINKS, Pause (Repeat) OFF • Wire to Sensor missing or bad • Sensor defective • Check wiring • Contact Customer Service 3 BLINKS, Pause (Repeat) ON • Sensor receiving interference • Determine source of interference • Check for sunlight or another opener on nearby door • Contact Customer Service 4 BLINKS, Pause (Repeat) ON • Source not sending pulses • Source defective • Contact Customer Service • Contact Customer Service For Help, call 1-800-35-GENIE or visit General Troubleshooting Problem What To Do Opener does not run 1 Check Lock switch on Wall Control Installation Poster from Wall Control 2 Check Power Source: • For Grounded Plug Connection – Plug a lamp into the electrical outlet used for the door opener a If lamp lights, power source is good b If lamp does not light, check fuse or circuit breaker • For Permanent Wiring Connection – Check fuse or circuit breaker 3 Check connections (see Wall Console Installation on Installation Poster): • At Power Head Terminals and Wall Control Door Opener starts 1 Check Wires to ensure that they are not cut (Staples can cut insulation and short Wires) for no apparent reason Replace any shorting Staples and shorted Wires 2 Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory and reprogram for remaining r...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias