|
Facilidade de uso
• Do you have an access door in addition to the garage door? If not, Model T7012 Emergency Access Device is required. SECTIONAL DOOR INSTALLATIONS • Do you have a steel, aluminum, fibreglass or glass panel door? If so, horizontal and vertical reinforcement is required (Installation Step 11). • The opener is normally installed at the centre of the door. If there is a torsion spring or centre bearing plate in the way of the header bracket or door bracket area, the opener may be installed within 300mm to the left or right of the door centre. See Installation Steps 1 and 11. • Look at the garage door where it meets the floor. It must close on the floor all the way across. Otherwise, the safety reverse system may not work properly. See Adjustment Step 3. Floor or door should be repaired. OPENER ARM MOUNTING LOCATION Must be mounted on a stile. Add an additional stile if required or offset mount the opener (see below and page 5). Attach arm 1/3 panel height from top at 10O as shown. Sectional Door Installation Excess MUST be removedRe-enforcementPanel Height10o1/3 Support bracket & fastening hardwareis required. page 17. — —FINISHED CEILINGExtension SpringTorsion SpringAccess DoorORHeaderSleeve BracketHeaderBracketTrolleyStraightDoorArmEmergencyReleaseRope & HandleDoor BracketGarageDoorCurvedDoorArmGarageDoorSpringHeaderWallCLOSED POSITIONRail AssemblyMotor Unit Excess MUST be removedRe-114A2845 4 OFF CENTRE INSTALLATION OF OPENER In situations where obstruction prevent mounting the opener centrally, offsetting the opener attachment is possible within the following range -1/4 Door width from centre. NOTE: Even though it is acceptable practise to off centre mount the opener, the further off centre the opener is mounted the more dependent is the door operation on a good installation. This relates to correct set-up of opener and track, and correct door balance. The installation of the IR Safety Sensor is recommended for an off centre mount application. ONE-PIECE DOOR INSTALLATIONS • Generally, a one-piece door does not require reinforcement. If your door is lightweight, you can refer to the information relating to sectional doors in Installation Step 11. • Depending on your door’s construction, you may need additional mounting hardware for the door bracket (Step 11). • The gap between the bottom of the garage door and the floor cannot exceed 6mm. Otherwise, the safety reverse system may not work properly. See Adjustment Step 3. The floor or the door should be repaired. AccessDoorGap between floor and bottom of door must not exceed 6mm.SafetyReversing SensorThe Chamberlain Group, Inc. Door with Track Installation (Cable -USA) SensorCLOSED Piece Door with Track AccessDoorGap between floor and bottom of door must not exceed 6mm.SafetyReversing SensorThe Chamberlain Group, Inc. Door with Track Installation (Cable -USA) Sleeve BracketDoorBracketStraightDoorArmCurvedDoor ArmTrolleyEmergencyReleaseRope & HandleRailGarageDoorHeaderWallSafetyReversing SensorCLOSED POSITION Safety Reversing SensorFINISHED CEILINGSupport bracket & fasteninghardware is required. See page 17. Safety Reversing SensorGap between floor and bottomof door must not exceed 6mm. HeaderWallAccess DoorHeaderSleeve Piece Door without Track required. Reversing DoorCLOSED POSITIONHeaderSleeve BracketHeaderBracketTrolleyStraightDoorArmEmergencyReleaseRope & HandleDoor BracketCurvedDoorArmHeaderWallRailGarageDoorChain 11//44DDoooorrWWiiddtthh1/4DDoooorrWWiiddtthh 114A2845 5 Carton Inventory Your garage door opener is packaged in two cartons Hardware for assembly and installation is shown on which contains the motor unit and the parts illustrated the next page. Save the carton and packing material below. If anything is missing, carefully check the until installation and adjustment is complete. packing material. Parts may be stuck in the foam. Straight DoorArm SectionCurved DoorArm SectionSafety LabelsandLiteratureChain Hanging Brackets1-Function RemoteControl Transmitter (1) Remote ControlTransmitter Visor ClipLight Lens (1) RailCentreSectionChain Spreader with Screws and Washers3-Function Mini RemoteControl Transmitter (1) TrolleyInner Trolley4-Piece Rail1-Piece RailDoor BracketRail StrapsHeader BracketHeader Sleeve BracketBell WireIlluminatedPush ButtonLight globeRemote ControlWall Mount BracketVibration IsolatorsChain Noise Reduction Pads 114A2845 6 Hardware Inventory Separate all hardware and group as shown below for the assembly and installation procedures. Spring/Trolley Nut (1)MasterLink (2) ASSEMBLYINSTALLATIONNOTICEHandleRopeLock Washer8mm (7) Hex Screw8mm x 20mm (4) Nut8mm (7) Carriage Bolt8mm x 65mm (2) Screw (2)Washered Screw 25mm (4) (mounted in opener) Anchors8mm x 40mm (6) InsulatedStaplesRail GreaseDry Wall Anchors (2) Screw6AB x 25mm (2) Carriage bolt (1) Stop Bolt (1) Ring Fastener (4) Sheet Metal Screw8mm x 13mm (2) Lag Screw8mm x 45mm (2) Lag Screw8mm x 40mm (4) Clevis Pin8mm x 32mm (1) Clevis Pin8mm x 13mm (2) Clevis Pin8mm x 25mm (2) 114A2...
Este manual também é adequado para os modelos :Portão automático - 1140 (2.37 mb)
Portão automático - 1145jg (2.37 mb)
Portão automático - 1146 (2.37 mb)
Portão automático - 1150 (2.37 mb)