Log:
Assessments - 5, GPA: 3.8 ( )

Instruções de Operação Allstar Products Group, Modelo 6500-P

Fabricante : Allstar Products Group
Arquivo Tamanho: 1.24 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If the down force adjustments are correct, the door will reverse within two seconds of contacting the object and travel to the Full Open position. If this does not occur, recheck the Limit Adjustments (Page 17) and Sensitivity Adjustments (Step 2 & 3, Above). NOTE: Any time adjustments are made to Limits or Sensitivity, YOU MUST RETEST THE OPENER FOR THE REVERSING FEATURE AT FLOOR LEVEL AS OUTLINED ABOVE. OPEN FORCE ADJUSTMENT CLOSE FORCE 104391 ADJUSTMENT 1 1/2” BLOCK OF WOOD LAID FLAT (2”X4”) 104392 F: OPERATION AND ADJUSTMENT F: OPERATION AND ADJUSTMENT INSTRUCTIONS A DAMAGED OR MALFUNCTIONING PHOTOELECTRIC ACCESSORY SYSTEM COULD ENABLE A GARAGE DOOR TO CLOSE ON PEOPLE OR PROPERTY, CAUSING SERIOUS INJURY OR DEATH. PERFORM THIS TEST MONTHLY TO ENSURE YOUR ALL-CLEAR IS WORKING PROPERLY. STEP 5: Testing the All-Clear™ Photosystem — Start the door in the close travel direction and then place an obstacle approximately 8" high by 12" wide in the path of the beam. The Red Pilot Light on the All-Clear™ Photosystem should go out. The door should stop and reverse to the full open position. With the door fully open and at rest, place the obstacle in the path of the beam once again. Activate the Standard Wall Push Button. The opener should revert to and remain in the PUSH AND HOLD mode of operation for close travel. IF THE GARAGE DOOR TRAVELS MORE THAN ONE INCH IN A DOWNWARD PATH AFTER RELEASING THE BUTTON, THE ALLCLEAR ™ SYSTEM IS MALFUNCTIONING. CHECK THE ELECTRICAL CONNECTIONS AND ALIGNMENT OF THE ALLCLEAR ™. STEP 6: Operating the Super Station (Deluxe Wall Pushbutton Station) Controls — The Super Station replaces standard doorbell-type pushbuttons to allow you to integrate fully with all the convenience and security features built into your 6000 Seriesgarage door operator. 1. Operator Open Pushbutton — Green-backlighting, arrow pointing up. Used to start the door upward. This button will also stop and reverse a door that is closing. The button has no effect on a door that is opening. The function of this pushbutton is automatically disabled when the Security slide switch is set to the “ON” position and the door is fully closed. 2. Operator Close Pushbutton — Green-backlighting, arrow pointing down. Used to start the door downward. This button has no effect on a door in motion. 3. Operator Stop Button - Red-backlighting, universal “STOP” within an octogon. Used to stop a door in motion. This button has no effect on a door that is stopped. 4. Operator Light Pushbutton —Yellow-backlighting, “Sun” symbol. Turns the operator light on and off, but does not activate the door operator. The operator light will stay on until turned off using this pushbutton, or until door operation is initiated, which overrides the function of this pushbutton and automatically turns the light off after 4-1/2 minutes. Operator STOP 5. Security Switch — Prevents unwanted door operation from pushbutton, key Button switches, keyless entry systems, radio controls, etc. When the Security Switch is moved to the ON position (towards “locked” symbol), with the garage door fully closed, signals from all of these devices are locked out by the operator. Such Operator Light devices will continue to work until the door is fully closed, allowing you to set Button the switch (when leaving on vacation, for example), leave the garage and close the door remotely. (NOTE: YOU WILL NOT BE ABLE TO OPEN YOUR GARAGE DOOR Security USING RADIO CONTROLS OR EXTERIOR ACCESS CONTROLS UNTIL Switch THE SECURITY SWITCH IS RETURNED TO THE OFF POSITION (“unlocked” symbol). THIS MUST BE DONE FROM INSIDE THE GARAGE.) When the Security Switch is engaged, the green lighting behind the Open/Close Pushbuttons is extinguished as an indication. 6. Security Disable Switch - located under and to the left of the Security Switch. Disables the Security Switch feature. Use if the garage door is the only entryway to the garage. 104394 Operator OPEN Button Operator CLOSE Button Security Disable Switch 19 20 For Opener Models: 6000, 6500, 6500-P and J6500 108389 OPERATOR WIRING DIAGRAM 21 Your 6000 Series Residential Garage Door Opener is furnished with an enhanced 2 Wire All-Clear™ Photosystem. New features include: Time-Saving Electrical Connections. No screw terminals! Just strip the ends of the wires back 5/16 inch and use the supplied wire nut connectors for a quick hook-up to pre-wired garages or to the wires you run on site. See the figure above applicable to your installation. Universal Wiring Capabilities. The All-Clear™ Photosystem can be wired in series or parallel combinations. Virtually any existing wiring can be used. See the figures above. Improved Sunlight Immunity. Under certain conditions, direct sunlight can overpower photobeam systems. We have provided an extra internal circuitry to reduce sunlight problems. When required, the position of the transmitter and receiver may be interchanged with out rewiring. 108971 WIRING AUXILIARY EQUIPMENT INSTALLATION CHECKLIST BEFORE PL...

Este manual também é adequado para os modelos :
Portão automático - 6000 (1.24 mb)
Portão automático - J6500 (1.24 mb)
Portão automático - 6500 (1.24 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias