Log:
Assessments - 6, GPA: 4.7 ( )

Instruções de Operação Chamberlain, Modelo 1300

Fabricante : Chamberlain
Arquivo Tamanho: 1.44 mb
Arquivo Nome : 817b0dac-e329-4282-9397-aae9fbda14bd.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This required safety device MUST NOT be disabled. – Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor. If it is necessary to mount the units on the wall, the brackets must be securely fastened to a solid surface such as the wall framing. Extension brackets (see accessories) are available if needed. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary. The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing. Invisible Light Beam Protection Area Sensor Beam 6" (15 cm) max. above floor Sensor Beam 6" (15 cm) max. above floor Facing the door from inside the garage 21 INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows. Garage door track installation (preferred): • Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door. Snap into place against the side of the track. It should lie flush, with the lip hugging the back edge of the track, as shown in Figure 1. If your door track will not support the bracket securely, wall installation is recommended. Wall installation (Figure 2 & 3): • Place the bracket against the wall with curved arms facing the door. Be sure there is enough clearance for the sensor beam to be unobstructed. • If additional depth is needed, an extension bracket (see Accessories) or wood blocks can be used. • Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on the wall at each side of the door, no higher than 6" (15 cm) above the floor. • Attach brackets to wall with lag screws (not provided). • If using extension brackets or wood blocks, adjust right and left assemblies to the same distance out from the mounting surface. Make sure all door hardware obstructions are cleared. Floor installation (Figure 4): • Use wood blocks or extension brackets (see Accessories) to elevate sensor brackets so the lenses will be no higher than 6" (15 cm) above the floor. • Carefully measure and place right and left assemblies at the same distance out from the wall. Be sure all door hardware obstructions are cleared. • Fasten to the floor with concrete anchors as shown. Figure 1 DOOR TRACK MOUNT (RIGHT SIDE) Indicator Light Lens Lip Sensor Bracket Door Track Figure 2 WALL MOUNT (RIGHT SIDE)InsideGarageWall Indicator Light Sensor Bracket Lens Lag Screws (Not Provided) Fasten Wood Block to Wall with Lag Screws (Not Provided) WALL MOUNT (RIGHT SIDE) Indicator Light Sensor Bracket Lens Extension Bracket (See Accessories) InsideGarageWall (Provided with Extension Bracket) (Provided with Extension Bracket) Figure 3 Figure 4 FLOOR MOUNT (RIGHT SIDE) HARDWARE SHOWN ACTUAL SIZE Carriage Bolt Wing Nut Staples 1/4"-20x1/2" 1/4"-20 22 Attach with Concrete Anchors (Not Provided) InsideGarageWall Sensor Bracket Lens Indicator Light MOUNTING AND WIRING THE SAFETY SENSORS Figure 5 Carriage Bolt 1/4"-20x1/2" Lens Wing Nut 1/4"-20 • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5). • Finger tighten the wing nuts. • Run the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling. • Strip 1/4" (6 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener terminal screws: white to 2 and white/black to 3 (Figure 6). ALIGNING THE SAFETY SENSORS • Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct. The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required. • Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place. • Loosen the receiving eye wing nut and adjust sensor until it receives the sender’s beam. When the green indicator light glows steadily, tighten the wing nut. TROUBLESHOOTING THE SAFETY SENSORS 1. If the sending eye indicator light does not glow steadily after installation, check for: • Electric power to the opener. • A short in the white or white/black wires. These can occur at staples, or at terminal connections. • Incorrect wiring between sensors and opener. • A broken wire. 2. If the sending eye indicator light glows steadily but the receiving eye indicator light...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias