Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  
Downloads : 0   Arquivo Tamanho: 1 mb   Fabricante : Viking Access Systems  
Categoria : Portão automático
@name

Use Table C (below) as a guide. 3. Use XLP (cross-linked-polyethylene) type of wire. This wire reduces the effects of moisture and other environmental events in altering the functionality of the vehicular loop detector. 4. Twist the lead wire at least 6 turns per foot. 5. Use BACKER-ROD to minimize damage to the loop detector wire prior to using the sealant. 6. Place the loop detector wire and adjust the sensitivity of the vehicular loop detector unit in a way to minimize the effects of the gate

Downloads : 5   Arquivo Tamanho: 1 mb   Fabricante : Viking Access Systems  
Categoria : Portão automático
@name

Overall Dimensions WARNING - For Installation By Qualified Personnel Only. .985" 14.724" 7.874" 4.33" 4.33" .394" 2.36" 2.36" 2.36" 5.12" Gear/Motor Unit Can Be Mounted Left or Right 1.50" 5.90" TECHNICAL SUPPORT 1 800 908 0884i TABLE OF CONTENTS ABLE OF CONTENTSABLE OF CONTENTS Parts Diagram/Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i Important Safety Information Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . .

Downloads : 0   Arquivo Tamanho: 1 mb   Fabricante : Viking Access Systems  
Categoria : Portão automático
@name

Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. 1. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. 2. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment pr





categorias