Meanwhile, please check if Alarm buzzer is beeping. (3) Try the field working condition by running some application programs on your computer and repeating step. (4) Check if the UPS is initiated properly to support a continuous operation. Important Notice: Please plug the UPS into the wall outlet to charge the UPS for over 8 hours before using the UPS. INTRODUCING THE FRONT PANEL Front Panel Explanation 43 21 5 1. Line LED ( ): Green Line LED remains at a standstill when Utility Normal. 2. Inverter LED ( ): Amber LED is on when the UPS is on Battery Backup mode. 1. Overload LED ( ): Red Overload LED is on when the UPS is on overload condition. 2. Fault LED ( ): Red Fault LED is on when the UPS is Abnormal. 3. Main Switch: a. To Control on/off the UPS when Utility is normal. b. To enable “DC-Start” Function when Utility fails. (To enable DC Start properly, you are recommended to connect <80% output load with the UPS only) P.S.: Make sure the computer connected to the UPS is switched on before enable the "DC-Start" function .You are not recommended to add some other computer or peripherals after DC-Start function is activated. REAR PANEL 1. AC Inlet 2. AC Fuse Holder w/fuse (230Vac: 6.5A) 3. Surge protection outlet: Do not connect your computer to those Outlets; otherwise, your data will be Lost in case of Utility failure. 4. Backup Outlets: (The device connected is protected by UPS.) 5. Computer Interface (True RS232 communication port). 6. RJ11/RJ45 Jacks (MODEM /LAN RJ45 JACKS) 3 CHECKLIST When your UPS malfunctions during operation, you may check the list below for proper adjustment. Should the adjustment still be in vain, please contact your sales agent for help. Situation Check Items Solution . Mains normal but Green 'Line' LED is not on. 1. Is the power switch on? 2.Is the fuse broken? 3.Is the power cord loose? 1.Press Main Switch on. 2. Change fuse w/same rating. 3. Re-connect the power cord properly. . Amber 'Inverter' LED flashes, alarm beep sharply, but no output Recharge the UPS for 24 hours. . Red "Overload" LED is on, and alarm deeply beeps every 4 seconds. Check to see load status if it is in overload. Remove some uncritical load. . Red "Fault" LED is on and alarm deeply beeps every 4 seconds. Check if the output load Connected is in short circuit or the UPS is overloaded 4. Remove some uncritical load connected. 5. Remove the short circuit condition by a technician. . UPS is on Battery backup mode and it shuts down auto- matically after approx. 4 min. Is there any output load Connected? The sleeping mode of the UPS Is activated, so the UPS is on Sleeping mode now. Just simply connect some load at the output then re-switch on the UPS to wake it up. . No LEDs display on the front panel Consult with your sales agent For help. No Communication between the UPS and the Computer connected. Is the RS232 cable properly connected? Re-connect the RS232 cable Properly. 4 SUPPORT If you have any problems with the A03-S801 UPS, please consult this manual. If you continue to have problems you should contact the dealer where you bought this device. If you have any other questions you can contact the Atlantis Land company directly at the following address: AtlantisLand spa Via Gandhi 5 Ing2,Scala A 20017 Mazzo di Rho(MI) Tel: 02/93906085, 02/93907634(help desk) Fax: 02/93906161 Email: info@atlantis-land.com or tecnici@atlantis-land.com WWW: All brand and product names mentioned in this manual are trademarks and/or registered trademarks of their respective holders. 1 INTRODUCTION AVERTISSEMENTS Nous avons tout fait dans le but d’eviter que dans le texte, dans les images et dans les tableaux qui sont dans ce manuel, dans le software et dans le har...