Fabricante : Viking
Arquivo Tamanho: 138.14 kb
Arquivo Nome : 6b6e9317-0565-4c6c-a41d-948356136842.pdf
|
Facilidade de uso
I IIn nns sst tta aal lll lla aat tti iio oon nn/ //A AAp ppp ppl lli iic cca aat tti iio oon nns ss A. Installing the SQRG-12 with the TMS-6X 1. Wiring Rear View of the TMS-6X RJ21X Male Jack (not included) 13.8V AC Adapter (included) Siemans # 566B3-50 Marconi # R66B3-50 1-6 C.O. Lines Punchdown Terminal Block with Split Center (not included) (V/S) Earth Ground 120V AC VIKING ELECTRONICS, INC. HUDSON, WI 54016 MUSIC RING VOLUMESQRG-12 L1, L2, L3 USE ONLY LISTED CLASS 2 POWER SOURCE 12-14 VAC L4, L5, L6 SEQUENTIAL RING GENERATOR VIKING ELECTRONICS INC. HUDSON, WI 54016 VIKING© MODEL SQRG-12 POWER 13.8V AC 1.25A MAX RESET TMS CONTROL LINE 1 2 3 4 ON 1 2 3 4 RJ21X J2 RJ21X J2 Trunk Inputs of PABX/KSU Note: Earth ground is required in ground start applications. Ground Start or Ring All Lines Loop Start 1 2 3 4 ON ON OFF DIP Switches 2. 2. ROW 1 Loop/Ground Start C.O. Lines ROW 2 TMS-6X ROW 3 SQRG-12 Pin, Color ROW 4 Open ROW 5 SQRG-12 Pin, Color ROW 6 Loop/Ground Start C.O. Lines 1T 1R L1, G L1, R 26, W/BL 1, BL/W 38, BK/G 13, G/BK 1T 1R 2T 2R L2, BK L2, Y 27, W/O 2, O/W 39, BK/BN 14, BN/BK 2T 2R 3T 3R L3, W L3, BL 28, W/G 3, G/W 40, BK/S 15, S/BK 3T 3R 4T 4R L4, G L4, R 29, W/BN 4, BN/W 41, Y/BL 16, BL/Y 4T 4R 5T 5R L5, BK L5, Y 30, W/S 5, S/W 42, Y/O 17, O/Y 5T 5R 6T 6R L6, W L6, BL 31, R/BL 6, BL/R 43, Y/G 18, G/Y 6T 6R * Earth Ground 50, V/S * Note: Earth Ground is only required in ground start applications. Notes: If the PABX does not recognize lines on the TMS-6X as busy and call crashing is observed, set up those lines as “incoming only trunks” on the PABX. If those lines must be used for inbound and outbound calls, you must use the special software TMX-PRAL. Contact Viking product support at (715) 386-8666 for more information. Do not install bridging clips on any connections which connect the two halves of the punch down terminal block. Bridge clips should only be installed as a method of bypassing equipment. In order for the SQRG-12 to work properly, the four-wire modular jack must be installed between the TMS CONTROL LINE on the SQRG-12 and the SQRG jack on the TMS-6X or TMS-12A. B. Installing the SQRG-12 with the TMS-12A 1. Wiring S312 11 10 9 S28 7 6 5 S14 3 2 1 ON OFF Note: For proper ground start operation, DIP switches 1-12 must be set to OFF as shown above. RJ21X Male Jack (not included) 13.8V AC Adapter (included) Siemans # 566B3-50 Marconi # R66B3-50 1-12 C.O. Lines Punchdown Terminal Block with Split Center (not included) (V/S) Earth Ground SEQUENTIAL RING GENERATOR VIKING ELECTRONICS INC. HUDSON, WI 54016 VIKING© MODEL SQRG-12 POWER 13.8V AC 1.25A MAX RESET TMS CONTROL LINE 1 2 3 4 ON 1 2 3 4 RJ21X J2 RJ21X J2 Trunk Inputs of PABX/KSU Note: Earth ground is required in ground start applications. Ground Start or Ring All Lines Loop Start 1 2 3 4 ON ON OFF DIP Switches Rear View of the TMS-12A MUSIC Viking Electronics, Inc. Hudson, WI 54016POWER 13.8VACINPUTS / OUTPUTS WARBLE VOLUME SQRG-12 TMS-RDMA TMS-RDMA ON 9 10 11 12 S312 11 10 9 S28 7 6 5 S14 3 2 1 ON OFF Rear View of the SQRG-12 2. Wiring Table for the TMS-12A Note: For proper ground start operation, DIP switches 1-12 must be set to OFF as Loop Start TMS-12A DIP Switches Ground Start TMS-12A DIP Switches ROW 1 Loop/Ground Start C.O. Lines 1T 1R 2T 2R 3T 3R 4T 4R 5T 5R 6T 6R 7T 7R 8T 8R 9T 9R 10T 10R 11T 11R 12T 12R * Earth Ground ROW 2 TMS-12A Pin, Color 26, W/BL 1, BL/W 27, W/O 2, O/W 28, W/G 3, G/W 29, W/BN 4, BN/W 30, W/S 5, S/W 31, R/BL 6, BL/R 32, R/O 7, O/R 33, R/G 8, G/R 34, R/BN 9, BN/R 35, R/S 10, S/R 36, BK/BL 11, BL/BK 37, BK/O 12, O/BK 44, Y/BN ROW 3 SQRG-12 Pin, Color 26, W/BL 1, BL/W 27, W/O 2, O/W 28, W/G 3, G/W 29, W/BN 4, BN/W 30, W/S 5, S/W 31, R/BL 6, BL/R 32, R/O 7, O/R 33, R/G 8, G/R 34, R/BN 9, BN/R 35, R/S 10, S/R 36, BK/BL 11, BL/BK 37, BK/O 12, O/BK 50, V/S ROW 4 Open ROW 5 SQRG-12 Pin, Color 38, BK/G 13, G/BK 39, BK/BN 14, BN/BK 40, BK/S 15, S/BK 41, Y/BL 16, BL/Y 42, Y/O 17, O/Y 43, Y/G 18, G/Y 44, Y/BN 19, BN/Y 45, Y/S 20, S/Y 46, V/BL 21, BL/V 47, V/O 22, O/V 48, V/G 23, G/V 49, V/BN 24, BN/V ROW 6 Loop/Ground Start C.O. Lines 1T 1R 2T 2R 3T 3R 4T 4R 5T 5R 6T 6R 7T 7R 8T 8R 9T 9R 10T 10R 11T 11R 12T 12R shown above. DIP Switch 2 3 11 Position UP DOWN UP DIP Switch 2 3 11 Position DOWN UP UP * Note: Earth Ground is only required in ground start or master / slave applications. Notes: If the PABX does not recognize lines on the TMS-12A as busy and call crashing is observed, set up those lines as “incoming only trunks” on the PABX. If those lines must be used for inbound and outbound calls, set DIP switch 3 to on and switch 2 to off, on the TMS-12A. Do not install bridging clips on any connections which connect the two halves of the punch down terminal block. Bridge clips should only be installed as a method of bypassing equipment. In order for the SQRG-12 to work properly, the four- wire modular jack must be installed between the TMS CONTROL LINE on the SQRG-12 and the SQRG jack on the TMS-12A. P Notes: If th...
Este manual também é adequado para os modelos :Auto respondedores - SQRG-12 (138.14 kb)