Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Pentair, Modelo 472645

Fabricante : Pentair
Arquivo Tamanho: 887.64 kb
Arquivo Nome : CommercialPoolHeatersOrderingIG.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


All rights reserved This document is subject to change without notice 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 Trademarks and disclaimers PowerMax, MegaTherm and the Pentair Commercial Pool and Spa logo are trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa, Inc. disclaims proprietary interest in marks and names of others. P/N 472645 Rev A - 05/22/06 Litho in U S A 2 Table of Contents MegaTherm MT Standard Features 500-5000..................................4 Model Nomenclature..............................................4 Code Options..........................................................4 Features and Options.............................................5 Special Codes/Options...........................................5 Heat Exchangers....................................................5 Powermax PM Standard Features 500-2000 Model Nomenclature............ Configurations...................... Additional Options................ Prices subject to change - call (800) 831-7133 for availability and lead times. 3 ~-J ~vl CD CD Standard Features MegaTherm MT (500-5000) Integral finned copper tube heat exchanger. ASME 160 lb. working pressure, 2-pass configuration Glass-lined cast iron headers Stainless steel burners Built-in integral draft hood (indoor models) 115/24V transformer for 24V control system Redundant safety gas valve Manual shut-off valve Manual pilot valve Pilot gas regulator Electronic operating control with remote thermometer Adjustable manual reset safety high limit Pressure relief valve (75 PSI) Two temperature gauges Terminal strip 2 amp fuse EM2 - pump time delay (500-1825) Power on/off switch Power on light Non-combustible base (500-1825 Outdoor) Integral pump (500-1825) Water flow switch (500-1825) Water pressure switch (2000-5000) Model Nomenclature 1 2 3 4 5 6 M MODEL MT-POOL SIZE MBTU/h 0500 2000 0600 2200 0715 2450 0850 2800 1010 3050 1200 3200 1430 3500 1670 3600 1825 4000 4050 4500 5000 LOCATION I-INDOOR E-OUTDOOR 9 10 11 12 13 FUEL N-NATURAL P-PROPANE IGNITION 04- SPARK 110V 09- SPARK 24V (500-1825) 18- SPARK 24V (2000-5000) 16- STND. PILOT VERSION 1-8 TUBE B-10 TUBE C-18 TUBE REVISION P-PUMP 500-1825 A- 2000-5000 FIRING MODE C-STD. ON/OFF HEAT EXCHANGER C-GLASS LINED/COPPER N-GLASS LINES/CU-NI K-BRONZE/COPPER S-BRONZE/CU-NI Indoor Units SIZE STANDARD UNIT* SYS 9/16/18 SYS 4 FOR FM & MINNESOTA SHIP WT lbs. 500 6,622 N/A 808 600 6,888 N/A 819 715 7,061 N/A 873 850 7,505 N/A 945 1010** 7,926 N/A 1041 1,200 8,325 N/A 1199 1,430 8,694 N/A 1280 1,670 9,417 N/A 1445 1,825 9,772 N/A 1570 2,000 13,273 17,055 1950 2,450 14,013 17,993 2100 3050 16,053 19,930 2250 3500 17,858 21,570 2510 4050 19,291 22,361 2750 4500 20,841 26,130 2900 5000 21,832 27,084 3200 Outdoor Units Size Standard Unit * Sys. 9/16/18 Sys. 4 for FM & Minnesota Ship Weight lbs. 500 7,693 N/A 855 600 7,900 N/A 949 715 8,153 N/A 1050 850 8,468 N/A 1100 1010** 9,170 N/A 1240 1,200 9,594 N/A 1410 1,430 9,990 N/A 1570 1,670 10,177 N/A 1622 1,825 10,976 N/A 1725 2,200 15,521 18,307 2320 2,800 17,590 20,324 2500 3,200 19,828 22,819 2840 3,600 20,820 23,677 3175 4,000 22,239 26,003 3940 4,500 23,252 27,750 3790 *Spark Ignition standard on Natural Gas and Propane models (Ignition 09). “Available as Model 999 for local jurisdictions that limit input to 1,000,000 BTU/h. CSD - 1 Code (JX) 500-2450: * low water cutoff (man. reset w/test button) * manual firing valve (2nd shutoff valve) * leak test valve * 100% lockout 2800-5000: * low water cutoff (man. reset w/test button) * manual firing valve (2nd shutoff valve) * multiple leak test valves * 100% lockout * high & low gas pressure switches CSD-1 + IRI Code Package (JD) 500-2450 * low water cutoff (man. reset w/test button * manual firing valve (2nd shutoff valve) * leak test valve * 100% lockout * normally open vent valve 2800-5000: * low water cutoff (man. reset w/test button * manual firing valve (2nd shutoff valve) * multiple leak test valves * 100% lockout * high + low gas pressure switches * normally open vent valve 14 15 16 OPTIONS XX- STANDARD UNIT FX- FM CODE HL- HIGH + LOW GAS SWITCHES JD- CSD1 + IRI CODE PACKAGE JX- CSD-1 LC- L.W.C.O. + 100% LOCKOUT LW-LOW WATER CUT OFF MX-MINNESOTA CODE FM Code (FX) 500-2450: * add CSD-1 2800-5000: * System 4 (see heater pricing) * low water cutoff (manual reset with test button) * manual firing valve (2nd shutoff valve) * multiple leak test valves * 100% lockout * high & low gas pressure switches * normally open vent valve * morotized safety valve California Code (LC) * order low water cutoff + 100% lockout CODE OPTIONS INCLUDE: M...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias