Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação Viper, Modelo Hayward 5500

Fabricante : Viper
Arquivo Tamanho: 752.77 kb
Arquivo Nome : cf9cf157-e3fd-419c-a35c-11e2605d3867.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This Owner's Guide should be given to the owner/operator of this cleaner to keep. Important Safety Instructions Important Safety Instructions Warning Read this entire Owner’s Guide before installing the Viper cleaner. Failure to follow safety warnings and owner’s guide instructions can result in severe injury, death or property damage. For additional free copies of the Owner’s Guide you can download them from or call (908) 351-5400 ext. 4700. Warning - Risk of Electrical Shock The Hayward Viper Automatic Pool Cleaner is designed to connect to a threaded 1-1/2 inch female pipe fitting on a dedicated return line that is powered by a 3/4 H.P. Booster Pump. You should have a licensed electrician install the cleaner’s booster pump. The Booster Pump must be installed in accordance with the National Electrical Code and all local code requirements. Failure to do so can result in serious injury or death. Warning - Risk of Injury Failure to follow the safety warnings below may result in severe injury, death or property damage. • Always disconnect and remove the cleaner and pressure hose before entering the pool. • Always handle with care. Do not let children or pets play with the cleaner; it is not a toy. • Always turn the Booster Pump OFF before handling cleaner (exception: initial setting of pressure, page 10). • Do not operate outside the pool. The Viper Cleaner and hoses contain high-pressure water jets that may cause injury. • Disconnect pressure hose from the universal wall fitting before removing the cleaner from the pool. • Never point any of the cleaner’s high-pressure jets, pressure hose or sweep hose at any person or pets. Important Information Caution - Risk of Equipment Damage • Always turn the Filtration Pump on before turning the booster pump on. Running the booster pump dry will damage the booster pump and is not covered by the Hayward warranty. • Always disconnect and remove the Viper cleaner and hoses from the pool before cleaning or backwashing the pool filter. • After cleaning or backwashing the pool filter, allow the filtration system to run for a minimum of five minutes or until all debris has been flushed from plumbing lines before reconnecting the Viper cleaner. • New plumbing lines must be flushed out before connecting the Viper cleaner. • The Viper cleaner should not be used to remove plaster dust or construction debris from new or renovated pools. • The Viper cleaner should not be used to remove excessive sand (dense debris) following wind or sandstorms. • Always disconnect and remove the Viper cleaner and hoses before chemically shocking the pool. • Only operate the Viper cleaner for the period of time necessary to clean the pool. Excessive use is unnecessary and will cause cleaner parts to prematurely wear. • Regularly inspect the cleaner and hoses; do not use if damaged or if any rough edges are visible on the cleaner; this can cause damage to the pool. • Only pick-up the Viper cleaner by its wing (Part A, page 4), never by the hose or bag. Disclaimer • Pool plaster is affected by age, water chemistry, etc. • Pool plaster can deteriorate over a period of time. • The integrity of "good" pool plaster is such that a pool vacuum cleaner – automatic or manual – cannot remove the plaster. • The integrity of "good" pool plaster is such that the plaster will cause wear on the cleaner, the cleaner will not wear out “good” pool plaster. • Vinyl pool liners are affected by age, sunlight, and water chemistry. • Vinyl pool liners can become brittle and weak. • Vinyl pool liners can be affected by the installation and the pool's surroundings. • Patterns on vinyl pool liners vary in quality. • When installing the Viper cleaner, you assume responsibility for the condition of the pool and the pool's surroundings and chemistry. Use Only Genuine Hayward Replacement Parts. 1 Contents Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 For Your Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Principal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Preparing the Pool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Tools Needed for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Connecting Viper Cleaner to Pool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Installing the Universal Wall Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Connecting Pressure Hose to Universal Wall Fitting… . . . . . . . ....


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias