Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Jacuzzi, Modelo J-300 J-375

Fabricante : Jacuzzi
Arquivo Tamanho: 5.29 mb
Arquivo Nome :
Língua de Ensino:
Ir para baixar



Facilidade de uso


WIRE SIZE MUST BE BLUJ6 BRNJ5 BRNBRNBLUBLKBLUBLUBRNBLUBRN BLU BLUBRN BRN 21 FLOW SWITCHHI - LIMIT / FREEZE SENSOR TEMPERATURE SENSOR J1 J2J3 F120A, 250VSC-20 PUMP 1PUMP 2 TRANSFORMER240 VACF1 JP142 31 6 5 8 7 HIHILO C Control Panel CIRC.PUMP J20 K1K2K3K4K5K6 K7 K8 J21J11J12J13J14J15J16J17J18J19 J7 J8 J9 J10 Logic Jumper Settings (Factory Defaults Shown)JP1 1-2 ON = 20A Logic JP1 1-2 OFF = 30A Logic JP1 3-4 ON = 2 Pump OperationJP1 3-4 OFF = 1 Pump OperationJP1 5-6 ON = 40A Logic (Remove JP1 1-2 Jumper) JP1 5-6 OFF = Leave Off for 20A or 30A LogicJP1 7-8 ON = Celsius Temperature DisplayJP1 7-8 OFF = Fahrenheit Temperature Display Heater2.7 kW @230 VAC J4 XW12VAC Output toWaterfall Light/Footwell LightController XWBlue wires 12 VACconstant voltage(connects to theyellow wires onthe transformer) Waterfall and Footwell lights can connect to anyplug on the DCU (P/N6560-134)Yellow ConnectorControl PanelAA 6560-134 GRN BLU BRN APPROPRIATE PER NEC AND/OR LOCAL CODES J-300 16.3 export J-335, J-345, J-355, J-365 and J-375 Models (50 hz) This wiring diagram is used for all Export 230 VAC 50 Hz spa models. J-300 J-300 export J-315 and J-325 models (50 Hz) This wiring diagram is used for all Export 230 VAC 50 Hz spa models. OzonatorOptional O 3 TB1230 VAC, 3-Wire Connection (50Hz, 1-Phase USE COPPER CONDUCTORS ONLY. WIRE SIZE MUSTBE APPROPRIATE PER NEC AND/OR LOCAL CODES 21 Flow SwitchHi-limit/Freeze SensorTemperature Sensor J2J3 F120A250VSC-20Circ. Pump MainPump Transformer230 VAC J4 HILO GRN Logic Jumper SettingsAll Export 50 Hz Models:JP1 1-2 ON = 20A Logic* JP1 1-2 OFF = 30A Logic*Factory Jumper SettingTemp. Jumper Settings (All Models):JP1 7-8 ON = Celsius Temp Display JP1 7-8 OFF = Fahrenheit Temp Display BLU BRN JP142 31 6 5 8 7 Heater Specifications• Export 50 Hz Model:2.7 kW @ 230 VAC J20 J21J12J14J16J11J15J13 J17 J7 J8 J9 J10 J5 J6 Heater IN Heater OUT F1 K5 K7 K8 BRNBRN BLU BLUBLU BRN BRN BLK BLU BRN BLU BRNJ1Control Panel X W 12VAC Output to Waterfall Light/Footwell Light Controller XW12 VAC From Transformer Blue wires 12 VACconstant voltage(connects to theyellow wires onthe transformer) LightDCU Waterfall and Footwell lights can connect to anyplug on the DCU (P/N6560-134)Yellow ConnectorControl PanelAA 6560-134 K1K2K3K4 J-300 J-300 optional stereo receiver Functions 17.1 stereo receiver Control Functions SATINFOAS-PSXBAS2ZONESUBWBANDSEARCHTOPMENUINTRPTRDMAUDIOENTERMODEMULTI- ENVIRONMENTPLAYERAQ-CD-398762341105111213141815161719202122 models equipped with the stereo option only: To start enjoying your new Stereo Receiver, please read the following operation instructions in their entirety. 1. power Button: Press PWR (Power) to turn deck on or off. 2. open Button: Press Open to flip down the front access panel for CD access. Gently insert CD into slot (DO NOT FORCE!) Make sure to close the front panel to prevent damage to the unit. • Eject Button (Not Illustrated): After releas...

Este manual também é adequado para os modelos :
Piscinas - J-300 J-315 (5.29 mb)
Piscinas - J-300 J-325 (5.29 mb)
Piscinas - J-300 J-335 (5.29 mb)
Piscinas - J-300 J-345 (5.29 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias