Instruções de Operação Weil-McLain, Modelo Maxi-Flow WMBH-95

Fabricante : Weil-McLain
Arquivo Tamanho: 111.98 kb
Arquivo Nome : e7140116-cb13-e7a4-bd95-7e3f72a1c96a.pdf

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


We recommend bypassing the heat exchanger while adjusting water chemistry. Stabilize chemistry to a pH of 7.2 - 7.8, with chlorine residual at 1.0 to 3.0 ppm. Damage to the heat exchanger due to improper water chemistry is not covered under the warranty. MAXI-FLO SWIMMING POOL HEAT EXCHANGERS Model WMPH-95 PVC Stainless Steel (minimum 10" long) Heating zone supply CD Щ Heating zone return c 0) Stainless Steel (minimum 10" long) ($ To the pool (5) PVC h® 1. Maxi-Flo Heat Exchanger 9. Filtration 2, Boiler 10. Pump 3. Boiler Water Circuit 11. Relay 4. Thermostat or Aquastat 12. Flow Switch 5. Gate Valve 13. Thermometer 6. Check Valve 14. Drain Valve 7. Circulators 15. On/Off Switch 8. Pool Water Supply 16. Flow Control Valve From the Pool SUGGESTED INSTALLATION This is only a concept drawing. Engineers must determine whether this system will work in each application and must ensure compliance with code requirements. Due to the high temperature at the heat exchanger connections, we recommend installing a stainless steel nipple (10" long) on the pool supply and return lines. Seal all threaded connections with an appropriate pipe dope. Perform a leak test to verify all joints. 636-000-043/0199...