Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Wayne, Modelo WIP100

Fabricante : Wayne
Arquivo Tamanho: 261.16 kb
Arquivo Nome : e665d1ce-7301-4969-9785-db699d26519f.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Pool Pumps Description This swimming pool pump is designed for use with permanently installed pools only. These pools can be either in-ground or above-ground. Unpacking After unpacking the unit, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts. General Safety Information This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following: Danger indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. Caution indicates a potentially minor or moderate injury. Notice indicates important information, that if not followed, may cause damage to equipment. CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. SAFETY GUIDELINES 1. Read these rules and instructions carefully. Failure to follow these MANUAL instructions could cause serious bodily injury and / or property damage. To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. This pump is for use with permanently installed pools. If specified, the pump may be used with hot tubs and spas. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to it’s original integrity. Pump only clear water. Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Personal injury and/or property damage could result. All wiring must be performed by a qualified electrician. The pump must be installed in compliance with all local codes and the National Electrical Code. 2. Do not install within an outer enclosure or beneath the skirt of the hot tub or spa, unless so marked. READ & FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS DO NOT DISCARD Installation LOCATION Disconnect, tag and lock out power source before attempting to install, service, relocate or perform any maintenance. Locate pump as close to pool/spa as possible. Install the pump on a hard, level surface that is dry, well ventilated and away from direct sunlight. The surrounding area should provide protection from the elements and ample room for maintenance and service. Ensure the drainage will flow away from the pump. Above ground pool pumps are not self-priming. If suction line valves are installed, the pump may be located above water level. Keep the vertical distance from the water level to a minimum. Otherwise, the pump must be located below filled water level to facilitate priming. Inground pool pumps are self- priming. Mount pump below water level for easy priming. If the pump must be located above the filled water level, keep the vertical distance to a minimum. GENERAL PLUMBING SOLVENT WELD CONNECTIONS Use rigid or flexible PVC pipe. Ensure pipe ends are clean and free of any flash caused by the cutting operation. Use the proper adhesive for the type of pipe specified. See list of recommended adhesives on page 2. NOTE: Use an adhesive primer to ensure adhesive joints are secure. Suregard P-3000 has a purple tracer to qualify in areas where codes specify a primer must be used. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2010 WAYNE Pumps For parts, product & service information 320403-001 4/10 visit 2 Operating Instructions and Parts Manual Installation (Continued) Consider climatic conditions when applying adhesives. Atmospheric conditions with high humidity will make the adhesive action of certain glues less effective. Follow the manufacturer's instructions. THREADED CONNECTIONS Use only Teflon® tape or equivalent on threaded plumbing connections. Other pipe compounds may damage threads. Do not use silicone or petroleum based compounds. Do not overtighten. Hand tightening plus 1/2 turn is sufficient. PUMP PLUMBING Suction pipe should be as large or larger than discharge pipe. Avoid using a suction pipe smaller than pump connection. 1. Keep the piping as straight and short as possible, and of suitable size. 2. Do not connect an elbow directly into the pump inlet. A length of straight pipe will allow proper entry of the water to the pum...

Este manual também é adequado para os modelos :
Piscinas - WIP150 (261.16 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias