Log:
Assessments - 1, GPA: 3 ( )

Instruções de Operação U-Line, Modelo BI-98

Fabricante : U-Line
Arquivo Tamanho: 1.1 mb
Arquivo Nome : BI98_30066E_install_guide.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cut-OutDimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Product Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Door Swing/Clearances Information . . . . . . . . . . . . . . 4 Reversing the Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Other Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 6 Custom 1/4" Thick Door Panel Insert . . . . . . . . . . . . . . 6 Checking Door Alignment . . . . . . . . . . . . . . . . . . . . . . 7 Adjusting Door Alignment . . . . . . . . . . . . . . . . . . . . . . 7 Water Supply Connection . . . . . . . . . . . . . . . . . . . . . . . 8 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 9 Leveling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installation of the BI-98 . . . . . . . . . . . . . . . . . . . . . . . . . 10 Grille Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installation Troubleshooting . . . . . . . . . . . . . . . . . . . . . 10 Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Start-Up Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 11 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 1 Follow Safety Precautions IMPORTANT PLEASE READ all instructions completely before attempting to install or operate the unit. • This unit requires connection to the water supply. Improper hook-up can result in substantial property damage! If you are unsure of your ability to safely connect the water supply to the unit, consult a licensed plumber for assistance. • This unit requires connection to a grounded (threeprong), polarized receptacle that has been placed by a qualified electrician in accordance with applicable electrical codes. Safety Alert Definitions Safety items throughout this guide are labeled with a Danger, Warning or Caution based on the risk type: DANGER Danger means that failure to follow this safety statement will result in severe personal injury or death. WARNING Warning means that failure to follow this safety statement could result in serious personal injury, or death. CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage. 2 02/2005 BI-98 Ice Maker General Precautions Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide: WARNING SHOCK HAZARD — Electrical Grounding Required. • Keep the unit unplugged throughout installation except during testing. • Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. • Never use an extension cord to connect power to the unit. • Always keep your working area dry. CAUTION • Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges. • Do not lift the unit by the door or door handle. • Do not install the unit behind closed doors or in any way that would obstruct airflow to the front grille, which may cause the unit to malfunction. 2 Inspect and Plan You have received a carton containing your BI-98 Ice Maker with a package inside containing a User Manual, a Product Registration Card and water connection parts. Complete and mail the Product Registration Card or register online at Once your unit is installed, keep the User Manual and this Installation Guide in a safe place for future reference. BI-98 units are available in vinyl clad cabinets with matching doors which have a slightly contoured handle across the top and are reversible. The doors have recessed front panels that will accept a custom 1/4 inch thick door panel. Please carefully follow the directions that apply to your unit and your intended design. Tools/Materials Required • Screwdrivers — slotted and Phillips head • 1/4-inch OD copper tubing and shut-off valve for water supply line • 1/4-inch thick door panel material and cutting tools Inspection Unwrap and inspect the unit on a flat, level surface capable of supporting its entire weight. Exterior Cleaning (As Required) Black and White Models: Black and white surfaces may be cleaned with a mild detergent and warm water solution. Do not use solvent- based or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotting. 02/2005 3 BI-98 Ice Maker Product Dimensions Prepare Site Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for water and electrical connections in the rear. Note: Unit can NOT be installed behind a closed cabinet door. Cut-Out Dimensions 8" TypicalCount...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias