Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Philips, Modelo SCF274/26

Fabricante : Philips
Arquivo Tamanho: 1.06 mb
Arquivo Nome :
Língua de Ensino: svenfrdenl
Ir para baixar



Facilidade de uso


All logos brands and product names are trademarks or registered trademarks of their respective holders and are hereby recognised as such. 42133 5435 010 #2 (10/07) GBFRSE 2 g) h) i) DE NL NO 90ml 3 4 5 GB Philips AVENT Express Electric Steam Steriliser Please take 5 minutes to read through the whole of this leaflet before you use your Philips AVENT Express Electric Steam Steriliser for the first time. As well as bottles and breastfeeding accessories, you can sterilise any other boilable items (please refer to the manufacturer’s instructions regarding sterilisation). Please keep these instructions safe for future use. These instructions are also available on our website. Hazard Warning • When in use, the steriliser contains boiling water and steam escapes from the vent in the lid. • Ensure the steriliser is placed on a firm level surface when in use. • Never open the unit when in use. • Always keep out of reach of children. • Always unplug from the mains when not in use. • Never place items on top of the steriliser. • To stop the steriliser during the cycle, unplug at the mains. • Take care when opening as steam can burn. • Never immerse the steriliser in water. • Never use the steriliser without water. • Failure to follow de-scaling instructions may cause irreparable damage. • There are no servicable parts inside the Express Electric Steam Steriliser. Do not attempt to open, service or repair the Express Electric Steam Steriliser yourself. Contents (see diagram A) a) Lid b) 2 x Upper basket c) Bottle rack d) Lower basket e) Central stem f ) Steriliser body g) Measuring cup h) Lead and plug i) Tongs NB: Upper and lower baskets are identical Before using your steriliser for the first time (see diagram B) Remove all items from inside the steriliser body. 1) Pour in exactly 90ml of tap water. 2) Assemble all the blue components (baskets, stem and bottle rack). Place the assembled components in the steriliser and put the lid on. 3) Connect the lead into the back of the steriliser and plug into the mains supply. The light should come on automatically. If it does not, press down on the steriliser switch. 4) At the end of the cycle the unit will switch off automatically and the light will go out. 5) Allow unit to cool, turn off at the mains, unplug and disconnect the lead from the back of the steriliser. 6) Remove baskets and bottle rack, pour away any remaining water and wipe dry. Before each use 1) Before sterilising, wash all items in mild soapy water and rinse. 2) Pour exactly 90ml of water into the steriliser body. If you add more than 90ml you will prolong the cycle time. If you use less than 90ml, your items may not be properly sterilised. NB: When loading, always ensure that the steam can effectively circulate around all surfaces and that any water can drain off easily. To sterilise up to six 260ml, 125ml or 330ml AVENT Bottles (see diagram C) 1) Slide the lower basket onto the central stem. 2) Thread 2 screw rings onto the central stem. 3) Slide the bottle rack down the central stem, with the neck facing down, until it rests on the top screw ring. 4) Place the teats through the centre of the holes in the bottle rack onto the lower basket. 5) Thread 4 screw rings onto the central stem. 6) Place the 6 inverted bottles in the bottle rack. 7) Push the upper basket onto the central stem until it rests on the catch. Place the 6 dome caps and tongs into the upper basket. 8) The upper basket is not required when sterilising 330ml bottles (see diagram C8). 9) Place the assembled unit into the steriliser body and put the lid on. 10) Put the lead into the back of the steriliser body and plug into the mains supply. Switch on. 11) Cycle times will vary depending on the load. After each cycle the unit will switch off automatically and the light will go out (approx. cycle time: 8 minutes). To sterilise the Philips AVENT ISIS Manual Breast Pump (see diagram D) 1) Click the ISIS Breast Pump body into the slot in the upper basket and arrange the other breast pump components as shown. Assemble remaining components of the ISIS Breast Pump in the lower basket. 2) Up to six bottles (not including screw rings, teats or dome caps) can be sterilised with the pump. 3) Place assembled unit into the steriliser body, put the lid on. 4) Put the lead into the back of the steriliser body and plug into the mains supply. Switch on. To sterilise narrow neck bottles and other feeding items Teats should be placed around the central stem in the lower basket and screw rings in the top basket, as they are too narrow for the stem. Always ensure items are positioned within baskets /racks to ensure effective circulation of steam. The bottle rack and/or upper basket can be removed to make more room. After sterilisation (see diagram E) 1) Do not remove the lid straight away. Let the steriliser cool down for 3 minutes. 2) Turn off at the mains, unplug and disconnect the lead from the back of the steriliser. 3) Wash your hands thoroughly before removin...

Este manual também é adequado para os modelos :
Acessórios do bebê - SCF274/27 (1.06 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias