|
Facilidade de uso
NB: When loading, always ensure that the steam can effectively circulate around all surfaces and that any water can drain off easily. To sterilise up to six 260ml, 125ml or 330ml AVENT Bottles (see diagram C) 1) Slide the lower basket onto the central stem. 2) Thread 2 screw rings onto the central stem. 3) Slide the bottle rack down the central stem, with the neck facing down, until it rests on the top screw ring. 4) Place the teats through the centre of the holes in the bottle rack onto the lower basket. 5) Thread 4 screw rings onto the central stem. 6) Place the 6 inverted bottles in the bottle rack. 7) Push the upper basket onto the central stem until it rests on the catch. Place the 6 dome caps and tongs into the upper basket. 8) The upper basket is not required when sterilising 330ml bottles (see diagram C8). 9) Place the assembled unit into the steriliser body and put the lid on. 10) Put the lead into the back of the steriliser body and plug into the mains supply. Switch on. 11) Cycle times will vary depending on the load. After each cycle the unit will switch off automatically and the light will go out (approx. cycle time: 8 minutes). To sterilise the Philips AVENT Manual Breast Pump (see diagram D) 1) Click the Breast Pump body into the slot in the upper basket and arrange the other breast pump components as shown. Assemble remaining components of the Breast Pump in the lower basket. 2) Up to six bottles (not including screw rings, teats or dome caps) can be sterilised with the pump. 3) Place assembled unit into the steriliser body, put the lid on. 4) Put the lead into the back of the steriliser body and plug into the mains supply. Switch on. To sterilise narrow neck bottles and other feeding items Teats should be placed around the central stem in the lower basket and screw rings in the top basket, as they are too narrow for the stem. Always ensure items are positioned within baskets/ racks to ensure effective circulation of steam. The bottle rack and/or upper basket can be removed to make more room. After sterilisation (see diagram E) 1) Do not remove the lid straight away. Let the steriliser cool down for 3 minutes. 2) Turn off at the mains, unplug and disconnect the lead from the back of the steriliser. 3) Wash your hands thoroughly before removing the sterilised items. 4) Remove the lid. 5) If necessary, shake excess water from items before assembling. 6) The tongs can be used to remove small items and to pull the sterile teats through the screw rings of the bottles. 7) The contents will remain sterile for up to six hours, following the end of the cycle, provided the lid is not removed. 6 8) Removed items must be used/assembled immediately or re-sterilised. Expressed milk can be stored in a sterile breast milk container in the refrigerator for up to 48 hours (not in the door) or in the freezer for up to 3 months. Infant formula should be made up fresh for each feed. 9) The steriliser must be left to cool for at least 10 minutes between each use to allow the thermostat to reset. 10) After each use, pour away any remaining water, rinse and wipe dry. Dishwasher Basket (see diagram F) 1) The upper and lower baskets can be clipped together to hold small items such as teats, breast pump parts, soothers, etc for washing in the top rack of your dishwasher prior to sterilisation. 2) To clip together, align the two baskets so that the indicators are opposite each other and snap the baskets together. To open basket, pull apart with fingers using side recesses. Warning: If your Philips AVENT items are washed in the dishwasher with dirty items covered with remnants of strong sauces, such as tomato sauce, they may discolour over time. Care of your steriliser You should de-scale your steriliser every four weeks to ensure it continues to work 100% effectively. It may be advantageous to use pre-boiled or filtered water in your steriliser in order to reduce limescale build up. EITHER: 1) Mix one sachet of citric acid (10gms) with 200ml of water. Pour into the empty steriliser. Do not put lid on. Switch on for 1-2 minutes, i.e. do not run a full cycle. Switch off at mains and leave to stand for 30 minutes. Drain and rinse out the steriliser. Run a full cycle empty with the lid on, using exactly 90ml of water. Wipe out the steriliser. (Citric Acid is available from most chemists – avoid contact with eyes as this may cause irritation. Keep out of reach of children). OR: 2) Pour 100ml vinegar mixed with 200ml cold water into steriliser. Allow to stand in the unit until any limescale has dissolved. Empty the unit and rinse thoroughly. Warnings 1) Under no circumstances should anything other than citric acid or vinegar be used for de-scaling as it may cause irreparable damage. 2) Do not use bleach or chemical sterilising solutions/tablets in your steam steriliser or on products to be sterilised. 3) Do not use abrasive, anti-bacterial materials or scourers to clean the steriliser. 4) Do not use softened water in the ste...
Este manual também é adequado para os modelos :Acessórios do bebê - SCF274/38 (2.17 mb)