Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Sony, Modelo ICD-P17

Fabricante : Sony
Arquivo Tamanho: 638.29 kb
Arquivo Nome : 3255789121.pdf
Língua de Ensino: en
Fotos e especificações  Sony  ICD-P17
Ir para baixar



por este dispositivo também tem outras instruções :
Ditado - ICD-P17 (644.05 kb)es
Ditado - ICD-P17 (650.75 kb)de
Ditado - ICD-P17 (635.89 kb)ru

Facilidade de uso


Record the serial number in the space provided below. Refer to these numbers whenever you call upon your Sony dealer regarding this product. Model No. ICD-P17 Serial No. Step 1: Installing the Batteries Slide and lift the battery compartment lid. Insert two LR03 (size AAA) alkaline batteries with correct polarity, and close the lid. If the battery compartment lid is accidentally detached, attach it as illustrated. 1 2 1 2 Clock setting display appears when you insert batteries for the first time, or when you insert batteries after the unit has been without batteries for a certain period of time. Please refer to Steps 2 to 3 in “Step 2: Setting the Clock” to set the date and time. Replacing the batteries The battery indicator on the display window shows the battery condition. When flashes, replace the batteries with new ones. When flashes, the batteries are exhausted and the unit will stop operation. Battery life* With continuous use, approx. 10 hours recording/8 hours playback is possible. * Using Sony alkaline batteries LR03 (size AAA) * When playing back through the internal speaker with VOL control at around 4 The battery life may shorten depending on the operation of the unit. Notes • Do not use manganese batteries for this unit. • When you replace the batteries, insert the new ones within 3 minutes after you removed the exhausted ones. Otherwise, the display may show the clock setting display or incorrect date and time when you reinsert the batteries. In this case, set the date and time again. The recorded messages and alarm setting, however, will remain. • When replacing the batteries, be sure to replace both batteries with new ones. • Do not charge dry batteries. • When you are not going to use the unit for a long time, remove the batteries to prevent damage from battery leakage and corrosion. Clock setting display appears when you insert batteries for the first time, or when you insert battery after the unit has been without battery for a certain period of time. In this case, proceed from step 2. Display the clock setting display. Set the date. 2 Press NxPLAY/STOP. The month digits will flash. 3 Set the month and day in sequence, then press NxPLAY/STOP. The hour digits will flash. 1 2 Press – . or >+ to display “SET DATE”. 3 Press NxPLAY/STOP. The year digits will flash. 1 Tip To set the date to Year 2003, display “03Y”. 2 Step 2: Setting the Clock 3 Set the time. 3 Set the minute. 4 Press NxPLAY/STOP at the time signal. The display will return to “SET DATE”. 5 Press MENU to exit from the menu mode. Recording Messages You can record up to 99 messages in each of the five folders (A, B, C, D, and E). Since a newly recorded message is automatically added behind the last recorded message, you can start recording quickly without searching for the end of the last recording. Note Before making a long recording, be sure to insert new batteries and check the battery indicator. Select the folder. Start recording. You do not need to keep pressing zREC/STOP while recording. 1 Press zREC/STOP. Stop recording. If you do not change the folder after you stop recording, the next time you record you will record in the same folder. To Do this pause recording* Press XPAUSE. During recording pause, the OPR indicator flashes in red and “PAUSE” flashes in the display window. release pause and Press XPAUSE or zREC/STOP. resume recording Recording resumes from that point. (To stop recording after pausing recording, press STOP.) listen to the current Press zREC/STOP or STOP to stop recording, recording then press NxPLAY/STOP. review the current Press NxPLAY/STOP during recording. recording instantly select the microphone You can select the microphone sensitivity to display sensitivity the following by pressing MIC SENS. HIGH: To record at meeting or in a quiet and/or spacious place. LOW: To record for dictation or in a noisy place. * About one hour after you pause recording, recording pause is automatically released and the unit goes into the stop mode. 3 2 e.g. XPAUSE Press zREC/STOP again. The unit stops at the beginning of the current recording. BBasic Operations * The display selected with the DISPLAY button appears. Information IN NO EVENT SHALL SELLER BE LIABLE FOR ANY DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE PRODUCT OR THE USE OF ANY PRODUCT. For the customers in the U.S.A. INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause har...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias