Facilidade de uso


Parts List Item No. Part No. Name Qty. 1 629080214 Insulated Lower Panel, Dual 1 2 29677 Rear Mounting Plate 1 3 620023904 Front Mounting Plate (For 6 and 8 Beverage Valve Units) 1 4 32990 Wire Connectors 4 5 50904 RTV Sealant, 3-oz Tube 2 6 620013301 Drip Tray Cover, Black 1 7 620500201 Gasket 150-In 8 620914101 Installation Instructions 1 9 70555 Screw, No. 8-32 By 1 5/16-In. long 2 10 71010 Captivating Plastic Washer, No. 8 2 11 91486 Cornelius Logo 1 ^ WARNING: Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment. 1. Remove lower panel assembly from both Units. 2. Relocate beverage valve key switch to right side of the beverage panel on one of the Units. This Unit will be positioned on the right side of the counter. A. Remove beverage panel access covers. B. Locate black and red wires of the key switch. Cut these wires approximately 2 inches from the crimp nut connection to the yellow wires. C. Loosen the key switch mounting nut and remove the key switch. Using a 7/8-inch deep socket will help access the nut. D. Remove plastic plug from right side of the beverage panel and insert into the left side key switch opening. E. Install key switch into the right side of the beverage panel and tighten mounting nut. F. Move black and red wires from left to right side of the beverage panel. Strip red/black wires and reconnect to the key switch using wire connectors (item 4) provided. G. Install beverage panel access covers. 3. Install Adaptor Kits if applicable for the type of ice makers used. 4. Apply self-adhesive gasket material (item 7) to the side of one Unit as indicated in Figure 1. Ends of the gasket should fit tight to each other. 5. Place Units into position on the counter. The Units must be at the same height and sitting level. The outside-outside dimension of the Units should be 60-3/8 inches (3/8-inch between the Units at the center). 6. Remove one screw from each base at the rear of the Unit and install rear mounting plate (item 2) to maintain the proper spacing between the Units (see Figure 2). Release Date: September 28, 2010 © 1998-2010, IMI Cornelius Inc. - 1 - Revision: B Publication Number: 620914101 ED2XX Dual Mounting Kit Installation Manual 7. Install front mounting plate (item 3) using the four beverage panel mounting screws at the center of the Units. The rectangular plate is for use with the six or eight valve Units. 8. Apply RTV (item 5) at the gasket-cabinet joint to seal any gaps between the Units, on all sides of the gasket. 9. Using one screw on each cabinet at the center of the Units (above the drip trays), install drip tray cover to match color of the drip tray. The drip trays must be at the same height along the edges for cover to fit properly. 10. Assemble two lon...

Este manual também é adequado para os modelos :
Dispensadores - ED2XX 629085101 (332.97 kb)
Dispensadores - ED2XX 29677 (332.97 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias