Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Culligan, Modelo Preferred Series

Fabricante : Culligan
Arquivo Tamanho: 95.64 kb
Arquivo Nome : 550cdbf8-1d8e-4d00-aa09-1a8f1719a956.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


01881923 Rev. D 01/06/03 DCO# 5378 Culligan® Preferred™ Series Drinking Water Filters Installation, Operation, and Service Guide SPECIFICATIONS Operating Pressure Range: 10 - 125 psi (0.7 bar - 8.6 bar) Operating Temperature Range: 35 - 100°F (2 - 38°C) Service Flow Rate: 0.5 gpm (1.9 Lpm) Capacity: 750 gal. (2,839L) Preferred 150 1000 gal. (3,785L) Preferred 250 300 gal. (1,135L) Preferred 350 For cold water use only NSF/ANSI 42 NSF/ANSI 53 ANSI ACCREDITED CERTIFICATION PROGRAM NSF's Certification Program NSF's Certification Program is accredited by the American is accredited by the Dutch National Standards Institute Council for Accreditation System Tested and Certified by NSF International against NSF/ANSI Standards 42 and 53 for the reduction of: Standard No. 42: Aesthetic Effects Chemical Unit Taste and Odor Reduction Chlorine Reduction Mechanical Filtration Unit Particulate Reduction 99.9+% reduction of particles one-half micron and larger in size Standard No. 53: Health Effects Chemical Reduction Unit Lead Reduction VOC Reduction (350 Only) Mechanical Filtration Unit Turbidity Reduction Cyst Reduction Asbestos Reduction Validated by WQA according to NSF/ANSI 42 and 53 for the claims listed by NSF International as verified and substantiated by test data. Check for compliance with state and local laws and regulations. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. Note that some states require licensed installers, and some states prohibit the use of saddle valves. INSTALLATION Culligan recommends that Preferred Series Drinking Water Filters be installed with a faucet dedicated to dispensing only filtered water. Such a faucet is available from Culligan by ordering P/N 01-0035-37*. Refer to the plumbing schematic shown in Figure 1 when completing this type of installation. Other recommended applications include point-of-use drinking water coolers, refrigerators, and ice makers. 4” (10.7 cm) Dia. Unit Dimensions with • Preferred 150 Cartridge 12-3/4” (32.4 cm) • Preferred 250 Cartridge 17-3/4” (45.1 cm) • Preferred 350 Cartridge 20” (50.8 cm) Figure 1 This filter system is supplied with fittings which are designed for use with 1/4 inch O.D. polyethylene tubing: available from Culligan by ordering P/N 00-4021-84*. 1. Select a location for the filter assembly which: • Provides a solid mount for the filter head. • Allows a minimum 2 inches (5 cm) of clearance under the cartridge. • Allows space for inlet and outlet water line connections. Note: The filter must be mounted vertically. 2. Provide an inlet water supply for the filter by tapping the cold water line. This connection should accommodate 1/4 inch O.D. polyethylene tubing and must comply with state and local laws and regulations. 3. Install the faucet or dispensing device according to the instructions provided with the device. 4. Refer to Figure 2 to determine the best filter bracket position to accommodate the water connections. 5. Install the 0.5 gpm flow restrictor fitting into the outlet port on the filter head using Teflon tape. Note: The restrictor is built into one of the elbow fittings. 6. Install the remaining 1/4 inch tubing fitting into the filter head inlet using Teflon tape. 7. Mount the filter head using the screws and washers provided. 8. Connect the inlet and outlet tubing to the inlet and outlet fittings of the filter. Double check the water connections to be sure that water will follow the direction-of-flow arrow on top of the head; water supply to inlet fitting, outlet fitting to faucet. 9. Install the filter cartridge as detailed in Figure 3. 10.Flush the cartridge for three minutes to purge the system of air. *Not tested or certified by NSF. WALL WALL 45° ° Illustration A Right Wall Mounting Illustration B 45° Head can be rotated a maximum of 45° from wall. WALL WALL 45° ° Illustration A Right Wall Mounting Illustration B 45° Head can be rotated a maximum of 45° from wall. C REMO 1. Shut off w Open serviced faucet to reliev 2. Turn cartridge to the left as far as possible. 3. Holding head firmly, pull cartridge downward and out of head. TRIDGE TION Align cartridge lug with head label. Holding head firmly, press cartridge fully 3. Turn cartridge to right until rotation stops. 4. Turn water on and run water for 3 minutes to purge cartridge of air. FILTER REPLACEMENT These drinking water systems must be maintained according to the manufacturer’s instructions, including timely replacement of filter cartridges. Follow the guidelines below to determine when the filter cartridge must be replaced in each system. Refer to Figure 3 for the service sequence. Preferred™ 150 Filter The filter cartridge must be replaced after every 750 gallons or one year of use (whichever comes first), or whenever there is a change in taste or odor or a noticeable decreas...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias