|
Facilidade de uso
routine use or not in use at home. · The appliance must be properly connected to an electrical power supply. (See: Connection · The cooling system of the appliance is filled with to Power Supply) . refrigerant and insulating substances which should · Do not use an extension cord. be separately treated and processed. Call your · Always disconnect the appliance from the nearest authorised service agent. If you are unable power supply before cleaning the appliance, to locate one, contact your local authorities or your or attempting repairs. distributor. Be careful not to damage the tubes on WARNING: the rear wall of the appliance (danger of pollution). . Repairs should be performed by qualified service personnel only. · Do not defrost the appliance with other electric appliances (for example a hair dryer) and never attempt to scrape/remove ice/frost with sharp objects. · The cooling system of the appliance is filled with refrigerant and oil ,so when the appliance is damaged, handle it with care and dispose of it in compliance with environmental protection safeguards. · The rating plate containing Model No and other technical data specific to this unit, is located either inside the appliance or outside on the rear wall. 3 Placing and Installation CHOOSING THE RIGHT PLACE WARNING Place the appliance in a dry and regularly ventilated room. Never place the appliance near heat emitting devices (e.g. cooking appliances, radiators, water heaters or similar devices) and do not expose to direct sunlight. The appliance should be positioned at least 2in. away from electric or gas cooking appliances and at least 12in. away from oil or coal fired stoves. If this is not possible, use an appropriate insulation barrier. Behind the appliance there should be a free space of at least 3in. . Kitchen units (cupboards) should be at least 2in. away from the appliance in order to assure adequate ventilation. There should be 4in. between both size of the chiller and other article. Instructions to avoid to the risk of fire , electric shock , or injury to persons. WIRING INSTRUCTIONS For your personal safety, this appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a power cord having an grounding conductor. The plug must be plugged into an appropriate wall outlet that is installed and wired in accordance with all existing local codes and ordinances. Consult a qualified electrician or serviceman if the wiring instruction are not clearly understood, or if doubt exists as to whether INSTALLATION Place the appliance firmly on a solid base. Some appliances have adjustable feet on the front side; use them to level the appliance. the appliance is properly grounded. CONNECTION TO POWER SUPPLY Connect the appliance power cord and plug to a properly grounded wall outlet. The required nominal voltage and frequency are indicated on the rating plate (inside the unit or on the exterior rear wall of the unit). 4 Description of the appliance (A) Adjustable Wine Shelves (For MCWC16MCG only) Shelves can be optionally placed on the guides inside the appliance where appropriate. Perishable items should be stored towards the back/rear of the shelves. i.e. the coldest part of the shelf. (B) Defrost Water Outlet The interior of the appliance is cooled with a cooling plate mounted in the rear wall. Under the plate there is a channel and an outlet for defrost water. Regularly check the defrost water outlet and the drain channel for blockage. They should always be kept free and clean of particles. WE RESERVE THE RIGHT TO ALTER THE SPECIFICATIONS WITH NO EFFECT ON THE OPERATION OF THE APPLIANCE. Temperature Control The temperature of the appliance is controlled by setting the thermostat knob to a desired setting. Temperature Selection To turn the control to the "OFF" position, rotate the To start the appliance turn the temperature control control knob to the "0" position. If the appliance knob to the position corresponding to the desired has been left out of use for some time, set the cooling. control to maximum or the "7" position for 2-3 Fig A (MCWC16MCG) see page 6 hours before turning to the desired position. If the Fig B (MCWC30MCG) see page 6 appliance is not being used for long time periods, The temperature will vary depending on the disconnect the plug and leave the door partially quantity of the item stored and on the frequency open. This will help to reduce mold/mildew from with which the door is opened. accumulating inside the appliance cabinet. Warning: Never set the temperature control to maximum or "7" position for more than 8 hours. 5 CONTROL KNOB Fig A (MCWC16MCG) Fig B (MCWC30MCG) Changes in ambient room temperature will affect the internal temperatures (choose correctsetting of the thermostat knob). . In STOP (0) position the appliance does not operate (cooling system is switched off ...
Este manual também é adequado para os modelos :Dispensadores - MCWC16MCG (1003.34 kb)