Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Yamaha, Modelo YHT-394

Fabricante : Yamaha
Arquivo Tamanho: 3.77 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


When “E-1” or “E-2” is displayed: i 1 1 Press iENTER once, and then press iCursor E to select “Exit.” 2 2 Press iENTER to finish YPAO, and set the unit to standby mode. 3 3 Check that the speakers are properly connected. 4 4 Turn on the unit, and then carry out YPAO again. When “E-5” to “E-9” is displayed: 1 1 Check that the environment is suitable for accurate measurement. 2 2 Press iENTER to switch the display. 3 3 Check that “Retry” is selected, and then press iENTER to carry out YPAO again. When “E-10” is displayed: 1 1 Press iENTER once, and then press iCursor E to select “Exit.” 2 2 Press iENTER to finish YPAO. 3 3 Switch the unit to standby mode. 4 4 Turn on the unit again, and then carry out YPAO. ¦ When a warning message appears after measurement Check the content of the message from the list of messages (.p. 24) to resolve the problem. You can confirm the speaker that has the problem when that speaker’s indicator lights up. NOTE Although you can apply the results of measurement when a warning message appears, doing so will not provide optimal sound. We recommend you resolve the problem and then carry out YPAO again. SL SRW-3:LEVEL YPAO VOL. Warning message (example) Speaker that has a problem. When multiple warning messages appear: Use iCursor D/ E to display other warning messages. When applying the results of measurement: Press iENTER to switch display, the use iCursor D / Eto select “Set” and press iENTER. When cancelling YPAO: Press iENTER to switch display, the use iCursor D / E to select “Cancel” and press iENTER. En 23 CONNECTIONS Set up the speaker parameters automatically (YPAO) ¦ Warning message ¦ Message list NOTE If the following messages appear, resolve the problems that have occurred and carry out the measurement process again. ¦ When a warning message appears before measurement Connect MIC! The YPAO microphone is Connect the YPAO not connected. microphone to the YPAO MIC jack on the front panel. Unplug HP! The headphones are connected. Remove the headphones. Memory Guard! The settings of this unit Set “Memory Guard” in are protected. the Setup menu to “Off.” ¦ Error message E-1:FRONT SP The unit was not able to find the front channel. Check that the left and right front speakers are connected correctly. E-2:SUR. SP The unit was only able to find one of side of the surround channels. Check that the left and right front surround speakers are connected correctly. E-5:NOISY The noise is too loud, preventing accurate measurements from being taken. Measure again in quiet surroundings. Turn off any devices in the room that may be emitting noise, or place them further away from the YPAO microphone. When this message is displayed, selecting “Proceed” will allow you to continue measuring. However, we recommend resolving the problem and measuring again, as continuing measurement without doing so will not give accurate results. E-7:NO MIC The YPAO microphone has been removed. While measuring, take care not to touch the YPAO microphone. E-8:NO SIGNAL The YPAO microphone could not distinguish a test tone. Check that the YPAO microphone has been installed correctly. Check that each speaker has been connected and installed correctly. The YPAO microphone or the YPAO MIC jack may be broken. Inquire at the retailer where you purchased this unit, or the nearest Yamaha service center. E-9:CANCEL You have carried out an operation that has cancelled the measuring process. Carry out the measuring process again. Do not operate this unit by, for example, adjusting the volume. E-10:INTERNAL An internal error has occurred. Carry out the measuring process again. Contact a Yamaha service center if “E-10” appears again. W-1:PHASE The speakers displayed are connected with the opposite polarity. Depending on the type of speakers you are using and the environment in which you have them installed, this message may occur even if the speakers are connected correctly. Depending on the type of speakers, “W-1” may display even if the speakers are connected correctly. Check that the speaker polarity + (plus), and - (minus) are correct. If these are connected correctly, you can use the speakers normally even this message appears. W-2:OVER 24m The speakers displayed Install the speakers with (80ft) are separated from the listening position by more than 24m, and cannot be adjusted correctly. 24m of the listening point. W-3:LEVEL The difference each channel is too loud or too low, and cannot be adjusted correctly. Check that all speakers are installed in the same surroundings. Check that the speaker polarity + (plus), and - (minus) are correct. We recommend the same speakers or speakers with as similar specifications as possible. Adjust the volume of the subwoofer. If “W-2” or “W-3” appears, you can apply measurement results, but they will not give optimal results. We recommend that you resolve the problem and carry out the measurement process again. En 24 I I I I PLAYBACK Basic playback procedure c Input selector m VOLUME +/n...

Este manual também é adequado para os modelos :
Home theater - YHT-294 (3.77 mb)
Home theater - YHT-594 (3.77 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias