Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Makita, Modelo 4097-20 15A

Fabricante : Makita
Arquivo Tamanho: 2.96 mb
Arquivo Nome : 58-14-3005d9.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Always position the GFCI as close as possible to the power source. page 5 TOOL ASSEMBLY WARNING! To reduce the risk of injury, always unplug tool before attaching or removing accessories or making adjustments. Use only specifically recommended accessories. Others may be hazardous. Assembling Dymorigs & Vac-U-Rig® Stands For Cat. No. 4125 & 4130 only (Fig. 1). Fig. 1 Handle spoke Cradle assembly Column Base Leveling screws (4) Column bolts Socket set screws (2) Hex bolt 1. Set the base on the ground. Loosen the hex bolt and nut (wrench not supplied). Raise the column upright. 2. To core vertically or horizontally, insert the large column bolt (provided in separate accessory bag) through the bottom of column and into the base. Tighten hex bolt and nut (wrench not supplied). To angle core, tilt the column to the desired angle and tighten the hex bolt and nut. Save the column bolt for future use when vertical or horizontal coring. 3. Tighten the two (2) black socket set screws located on the base with the supplied wrench. 4. Screw the four (4) handle spokes (provided in separate accessory bag) into the hub on the cradle assembly. For Cat. No. 4115 & 4120 only (Fig. 2). Handle spoke Column Leveling screws (4) Column bolts (2) Lock washers Fig. 2 Cradle assembly Base 1. Set the base on the ground. 2. Remove two (2) bolts and two (2) lockwashers from accessory bag. 3. Place the column in the slot of the base. 4. Insert two (2) bolts and two (2) lockwashers and tighten securely. page 6 Moving the Handle to the Other Side For Cat. Nos. 4125 & 4130 only (Fig. 3). Fig. 3 Bubble Socket level Socket Ammeter gauge screws (4) screw Meter box Cradle lock Cradle 1. Tighten the cradle lock. 2. Loosen the socket head screw and remove the meter box. 3. Remove four (4) socket head screws holding the spoked handle housing. 4. Turn the assembly around 180°. 5. Replace the four (4) socket head screws and tighten securely. Fig. 4 Socket screw Ammeter gauge Meter box Socket screw and washer Cradle 6. Attach meter box to opposite side (see "Mounting the Meter Box"). For Cat. Nos. 4115 & 4120 only (Fig. 4). 1. Loosen the cradle lock. 2. Raise the cradle to the maximum height. 3. Lift the cradle an additional 1/2" by hand. 4. Tighten the cradle lock. 5. Loosen the socket head screw and remove the meter box. 6. Remove the meter box stud from the cradle. 7. Remove the screw and washer from the end of the pinion shaft. 8. Remove the handle and pinion shaft assembly. 9. Turn the assembly around 180° and insert into cradle. 10. Replace the screw and washer and tighten securely. 11. Replace the meter stud on the side opposite the handle. 12. Attach meter box to opposite side (see “Mounting the Meter Box”). 13. Loosen the cradle lock and lower the cradle until the pinion engages the rack. 14. Tighten the cradle lock. Mounting the Meter Box For All Catalog Nos. (Fig. 3 & 4). A meter box is standard equipment with the Vac-U-Rig®, but it must be purchased separately for other Dymorigs...

Este manual também é adequado para os modelos :
Brocas e shuropopverty - 4097-20 15A (2.96 mb)
Brocas e shuropopverty - 4004 20A (2.96 mb)
Brocas e shuropopverty - 58-14-3005d9 (2.96 mb)
Brocas e shuropopverty - 4130 (2.96 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias