You can select a power level 850 W, 1300 W or 2150 W. If 850 W is selected, 850 W digits are lighted and only the upper heating element works. If 1300 W is selected, 1300 W digits are lighted and only the lower heating element works. If 2150 W is selected, 2150 W digits are lighted and both the upper and lower heating elements work. In Delay mode, machine defaulted heating power is 2150 W and can't be adjusted. Fig. 8 shows a heating power level 2150 W, the present clock time 12:10, and the real-time heating mode. 5. Real-time Heat / Warm Setting With machine powered on, as described in Item 10, press Mode button to enter Real-time Heat / Warm mode with real-time heat indication lighted on. According to settings, machine will automatically starts to heat or keep warm. The machine has a thermostat function, by which, the machine goes into warm keeping status when it reaches the temperature setting value. In warm keeping status, machine automatically starts heating when actual water temperature is 5 (for setting value lower than 55 ) or 10 (for setting value equal to or above 55 ) lower than the setting value, until reaching setting temperature again. It repeats in this way. HEATING SET HEATING ACTUAL Fig.8 Fig.9 Example: Fig. 9 shows real-time heat / warm status with heating power 1300W and temperature setting 75 . 6. Medium Warm Setting With machine powered on, as described in Item 10, press Mode button until it enters Medium Warm operation mode (with Medium Warm indication on the display). (Fig.1) Remarks:the permitted error limit of above parameters is 10% (except the rated temperature). Front View Bottom View I: Drain A B d1 I a1 b1 C1 Dimensions Attentions in installation During installation, adequate space must be reserved for future maintenance and repair. If the water heater is installed within decoration boards, the right board shall be removable to facilitate removing the plastic cover during maintenance. City water inlet pressure shall not be less than 0.05 Mpa. Electric water heater shall be installed indoors with ambient temperature above 0 . The pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss. The mounting wall shall be firm and reliable to support twice the weight of water heater full of water. Non-load bearing walls or air brick walls must have corresponding protective measures like additional support, wall-through screws or back boards. Electric water heater shall be located in a place easy for use, maintenance and with a floor drainer. In case the tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users. Power socket for water heater shall be in a dry place free of water splash to avoid nonnormal work of the water heater. (splash-proof box is preferred) Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no random modification. The safety valve pressure relief vent shall keep open to the air. Do not block it. To ensure safety, water heater shall use a separate socket (not multi-purpose socket) and be reliably grounded. Socket quality shall comply with local standard. Check with a neo-electroscope the line and neutral are not wrongly connected. Only after confirming the tank is full of water, no water leakage at various connections and power supply meets requirements, power can be turned on to start heating. 80L 50L 60L 100L d1 100mm 100mm 100mm 100mm FCD-JTHMG50- E FCD-JTHMG60- E FCD-JTHMG80- E FCD-JTHMG100- E 22kg 25kg 29kg 34kg 671mm 765mm 876mm 1052mm 442mm 442mm 479mm 479mm 410mm 410mm 450mm 450mm Model Net Volume Weight a1 b1 c1 Rated temperature 75 75 75 75 Control Panel Illustration Mode Power On/Off HEATING KEEPING SET ACTUAL 1. Set Button 2. Temperature and Clock Time Increase Button 3. Temperature and Clock Time Decrease Button 4. Real-time Heating Indication 5. Medium Warm Indication 6. Night Power Indication 7. Heating Power Indication Area 8. Heating Indication 9. Delay Indication 10. Intelligent Indication 11. Mode Button 12. Power Level Selection Button 13. On/Off Button 14. Warm Keeping Indication 15...

Este manual também é adequado para os modelos :
Brocas e shuropopverty - SILVER SEA-OX FCD-JTHMG80- E (532.53 kb)
Brocas e shuropopverty - SILVER SEA-OX FCD-JTHMG100- E (532.53 kb)
Brocas e shuropopverty - SILVER SEA-OX FCD-JTHMG50- E (532.53 kb)
Brocas e shuropopverty - SILVER SEA-OX FCD-JTHMG60- E (532.53 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias