|
Facilidade de uso
2 SEC, 3 SEC, 5 SEC, 10 SEC, 20 SEC, 40 SEC, 1 MIN, 2 MIN, 3 MIN, 4 MIN, 5 MIN, 10 MIN, 15 MIN (Default setting: 1 MIN) ALARM TRIGGER (Default setting: ALARM) This sets an alarm trigger (a signal for alarm recording to begin) that will become the condition for the operation of alarm recording. 1 Select an alarm recording starting signal from the menu. • ALARM: Alarm recording starts when an external alarm reacts. • SENSOR: Alarm recording starts when a motion sensor reacts. • ALARM AND SENSOR: Alarm recording starts when an external alarm and motion sensor both react at the same time. • ALARM OR SENSOR: Alarm recording starts when either an external alarm or a motion sensor react. External alarm detection: This is when external sensor information (such as the opening or closing of a door switch) is input to the digital video recorder’s alarm input terminals while the digital video recorder is online. Motion sensor detection: This is when the motion sensor settings cause movement to be detected on the monitor screen. Click [SAVE] to complete the settings (or changes) for the sub-menu that is displayed on the screen. The number of alarm recordings available under the conditions that have been set will be displayed in parentheses for reference. English 17 Menu Setting Procedures 10. ALARM DURATION SET The duration of alarm recording can be set separately for each camera. The DURATION setting for each camera that is made using the [ALARM DURATION SET] menu is effective when [DURATION] in the [ALARM RECORDING] menu is set to “INDIV.” (See p. 16) 1 Select the alarm recording duration for each camera from the menu. 5 SEC, 10 SEC, 20 SEC, 40 SEC, 1 MIN, 2 MIN, 3 MIN, 4 MIN, 5 MIN, 10 MIN, 15 MIN, CC (Default setting: 5 SEC) 2 Click [SAVE] to set (or change) the alarm recording durations for each camera. Screen example for DSR-3009 model Screen example for DSR-3016 model 11. DISPLAY SET This specifies the information to be displayed on the monitor by selecting “ON” or “OFF” in the menu. Because this setting specifies the information to be displayed on the monitor that is connected to the main unit, it will have no effect on the computer screen. DATE (Default setting: ON) ALARM TYPE (Default setting: ON) Current date or recording date Type of alarm recording For alarm recording: “ALARM” is displayed. TIME (Default setting: ON) For pre-alarm recording: “PRE” is displayed. Current time or recording time QUALITY (Default setting: ON) Quality of images being recorded or played back REC RATE (Default setting: OFF) Recording rate for images being recorded or played back ALARM COUNT (Default setting: ON) Cumulative number of alarms The maximum count that can be displayed is 9999. If the count exceeds this number, it will be reset to 0. Click [SAVE] to complete the DISPLAY SET menu settings (or changes) that are displayed on the screen. 18 English Menu Setting Procedures 12. RS-232C/RS-485 SET This displays information related to the digital video recorder’s interface. This menu only lets you check the settings; it cannot be used to change the settings. CONTROL This shows the type of interface being used to control the digital video recorder. • RS-232C: Control by RS-232C • RS-485: Control by RS-485 DATA SPEED This shows the RS-232C or RS-485 communication speed. • 2400/4800/9600/19200(bps) STATUS INFO For RS-485 communication, this specifies whether status information is to be transmitted or not. • ON: Status information is to be transmitted. • OFF: Status information is not to be transmitted. 13. BUZZER SET ALARM INFO For RS-485 communication, this specifies whether alarm information is to be transmitted or not. • ON: Alarm information is to be transmitted. • OFF: Alarm information is not to be transmitted. ADDRESS This shows the address when RS-485 has been selected. • Valid settings range from 0 to 127. This enables the warning buzzer to sound as necessary. Select “ON” or “OFF” for the menu item settings. These settings only cause a buzzer to sound at the digital video recorder. They do not cause a buzzer to sound at the computer. ALARM (Default setting: OFF) This causes the buzzer to sound when there is an alarm. DISK FULL (Default setting: ON) This causes the buzzer to sound a warning when the free space remaining in the hard disk recording reach a preset value. (See p. 11) DISK ERROR (Default setting: ON) This causes the buzzer to sound a warning if a hard disk error has occurred. LOCK WARNING (Default setting: ON) This causes the buzzer to sound a warning if an unauthorized operating button is pressed when the security lock is on. The buzzer sounds twice during a 0.5-second cycle. KEY IN (Default setting: OFF) This causes the buzzer to sound a key operation beep when an operating button is pressed. NON REC (Default setting: OFF) This causes the buzzer to sound a warning when recording stops. Click [SAVE] to complete the BUZZER menu settings (or changes) that are displayed on the screen. English 19 Menu Setting Proced...
Este manual também é adequado para os modelos :DVD-player - DSR-3009 (2.06 mb)