Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação Assa, Modelo E5496LN

Fabricante : Assa
Arquivo Tamanho: 1.79 mb
Arquivo Nome : c9417f1d-4a96-47e2-97d2-a02c5fe1e464.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


FINISHES PVD Lifetime Finish Physical Vapor Deposition (PVD) is a technologically advanced finish coating that provides the ultimate surface protection against environmental elements and everyday wear and tear. PVD matches clear coated finishes in appearance, yet surpasses them in durability. Yale® warrants all its PVD finishes against corrosion, tarnish, wear, discoloration and peeling for the lifetime of the part to which it has been applied. Ask your sales representative for specific warranty information. ANSI Code Finish Description 605e* Bright Brass, PVD 606e* Satin Brass, PVD 609 Satin Brass, Blackened, Satin Relieved, Clear Coated 612 Satin Bronze, Clear Coated 613e* Satin Bronze, Oxidized, PVD 616 Satin Bronze, Blackened, Satin Relieved, Clear Coated 619 Satin Nickel Plated, Clear Coated 625 Bright Chrome Plated 626 Satin Chrome Plated 693 Black Powder Coat *PVD finish is standard for customers desiring a non-wearing finish. CERTIFICATIONS CONTENTS Basic Operation & Functions . . .3 Features & Benefits . . . . . . . . .4-5 Specifications . . . . . . . . . . . . . . . .6 Lever Designs . . . . . . . . . . . . . . .6 Cylinders . . . . . . . . . . . . . . . . .7-8 Options & Accessories . . . . . . . .8 Strikes and Latchbolts . . . . . . . . .9 Ordering Information . . . . . . . . .10 Architectural Specification . . . . . .11 A.D.A. The eBOSS meets accessibility guidelines of the Americans with Disabilities Act and the requirements of the Uniform Federal Accessibility Standards and ANSI 117.1, all requiring ease of accessibility for the handicapped. The eBOSS keypad also meets ADA 12-button telephone requirements. ANSI Grade 1 ANSI 156.2 Fire Listings UL - cUL Fire Label for all door functions up to 3 hours. WARRANTY The eBOSS E5400LN Series Cylindrical Lock keypad, printed circuit board and components are warranted to be free from defects in workmanship and materials under normal use and service for 3 years from date of delivery. In addition, the lockset carries a lifetime warranty against lever sag and lever spring breakage. PVD Finish also comes with a lifetime warranty. Ask your sales representative for complete warranty information. Page 2 eBOSS Electronic Lockset OPERATION BASIC OPERATION The outside lever is always locked except when the lock is in passage mode. The eBOSS™ allows up to 94 individual user codes to be valid. Codes may be from two to seven digits in length, and digits may be repeated. All programming is accomplished easily from the keypad utilizing LED and audible guidance. Changing codes takes only a matter of seconds for an authorized user. • User enters a valid code (2-7 digits) followed by the [*] key. • Lock will unlock (green LED) for a user definable duration of 1-255 seconds (default 4 seconds), then re-lock. • If lock is in lockout mode, the yellow LED will light, indicating denied entry. If enabled, the green LED will light upon each depression of a key and for the duration that the lock is unlocked. If the audible sounder is enabled, it will beep concurrently with the LED as keys are depressed. If an invalid code is entered, the red LED will light and an audible sound sequence of one long beep, followed by four short beeps, will indicate denied entry. FUNCTIONS E5496LN - Mechanical key can be used to retract latchbolt for entry E5486LN - Non-key override PROGRAMMABLE FEATURES All standard programming of the eBOSS is easily performed through the keypad. • Master Code – Assigns Supervisor Code and Emergency Code. • Supervisor Code – Allows all programming of the controller except for changing Master Code. • User Codes – Used for standard entry. 94 User Codes may be programmed into the eBOSS. • Emergency Code – Allows emergency entry of the lock system when the controller low battery voltage is in the “black out” condition or if the lock is in the Lockout mode. • Lockout Code – Restricts User Codes from the ability to gain access. Only the Supervisor Code and Emergency code can override. • Passage Code – Enables the passage feature, maintaining the lock unlocked. • Key Press Feedback - Enables or disables the LED indicators or audible sound features of the lockset. • Factory Code Reset – Resets all user definable functions to factory default settings. Will not reset Specialty Codes or User Codes. • Re-Lock Duration – Adjusts the duration the lock remains unlocked from 1-255 seconds. Default is 4 seconds. • Keypad Lockout – Deters tampering by disabling the keypad after three successive failed attempts or after 25 successive key presses without a valid code. Default is 10 seconds but user programmable from 1 to 255 seconds. OPERATIONAL MODES • Secure – Normal locked state. Any assigned user code can gain access. • Lockout – Lockset will not accept any assigned user codes except for the Supervisor and Emergency Codes. • Passage – Unlocked state BATTERY REPLACEMENT The inside battery cover is easily removed for battery replacement. Each lock contains six alkaline “AA” batteries...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias