Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Philips, Modelo SC2006/11

Fabricante : Philips
Arquivo Tamanho: 2.85 mb
Arquivo Nome :
Língua de Ensino: enfrnl
Ir para baixar



Facilidade de uso


recommended light intensities (1-5) In the table below, ‘x’means that the appliance is not suitable for you. Skin colour and characteristics: White (always sunburn, no tanning) Beige (easysunburn, minimal tanning) Light brown (sometimessunburn, good tanning) Mid brown (rarely sunburn, fast and good tanning) Dark brown (rarely sunburn, very good tanning) Brownish black and darker (rarely to never sunburn, very dark tanning) Body hair colour : dark blond/light brown/brown/ dark brown/black 4/5 4/5 4/5 3/4 1/2/3 x white/grey/red/ light blond x x x x x x important To check whether Philips Lumea Precision Plus is suitable for you, see section ‘For whom is Philips Lumea Precision Plus not suitable?’. If your skin has been exposed to natural sunlight or an ar tificial tanning method, it may be darker than during the previous treatment. Check the table above to determine which settings are suitable for your skin colour. Tanning advice Sun exposure before treatment -If your skin is tanned, perform a skin test (see chapter ‘Using the appliance’, section ‘First use’) on the area to be treated to determine the appropriate light intensity. A failure to do so causes a risk of developing skin reactions after treatment with Philips Lumea Precision Plus. -Wait at least 48 hours after sunbathing before you use the appliance. Sunbathing can cause skin to darken (tan) and/or can cause sunburn (reddening of the skin). 16 EngliSh -After these 48 hours, check the skin for any remaining sunburn. Do not use Philips Lumea Precision Plus as long as sunburn persists. -When the sunburn has disappeared, perform a skin test (see chapter ‘Using the appliance’, section ‘First use’) on the area to be treated to determine the appropriate light intensity. Sun exposure after treatment -Wait at least 24 hours after treatment before you expose treated areas to the sun. Even after 24 hours, make sure that the treated skin does not show any redness from the treatment anymore before you expose it to the sun. -Cover treated areas when you go out into the sun or use a sunblock (SPF 30+) in the two weeks after treatment. -Exposing treated areas to sunlight without protection immediately after treatment can increase the risk of adverse side effects and skin reactions. See chapter ‘Using the appliance’, section ‘Possible side effects and skin reactions’. Tanning with artificial light -Follow the instructions in ‘Sun exposure before treatment’ and ‘Sun exposure after treatment’ above. Tanning with creams -If you have used an ar tificial tanning lotion, wait until the ar tificial tan has fully disappeared before you use Philips Lumea Precision Plus. Note: For more details on unwanted skin reactions, see chapter ‘Using the appliance’, section ‘Possible side effects and skin reactions’. Using the appliance Check the recommended light intensities table in chapter ‘Preparing for use’, section ‘Setting the light intensity’ to determine which light intensities are most suitable for your skin and body hair colour. Use the appliance in a well-lit room; this reduces the perceived brightness of the flash. Shave the area you intend to treat before you use the appliance (see chapter ‘Preparing for use’, section ‘Preparing treatment areas’). If the treatment becomes intolerably painful at any point in time, reduce the light intensity setting until the treatment is comfortable again. If you notice skin reactions stronger than slight redness, stop the treatment immediately and read section ‘Possible side effects and skin reactions’ in this chapter. Choosing the right attachment -Body attachment The body attachment can be used to treat unwanted body hair on all body areas below the neck (for exceptions, see chapter ‘Impor tant’, section ‘Contraindications’).The body attachment can cover an area of 4cm. and has been specially designed for faster treatment of larger areas like legs. Do not use the body attachment on the face. EngliSh 17 -Precision attachment The precision attachment includes an additional integrated light filter and can be used for extra-safe treatment of unwanted facial hair on the upper lip, chin and sideburns. It may also be used on other sensitive areas of the body, such as the underarms and bikini area or hard-to-reach areas. Never use around the eyes and near the eyebrows. First use and skin test 1 2 Choose the attachment appropriate for the area you intend to treat. Choose an area close to the area you intend to treat. Note: Before you use the appliance on the upper lip, chin or sideburns, choose a mole- and hair-free area below your ear to perform the skin test. 3 Press the on/off button to switch on the appliance. The appliance always starts automatically at the lowest setting. , 4 5 6 Apply one flash at the lowest recommended intensity for your skin type (for instructions on how to release a flash, see steps 6 to 9 of section ‘Subsequent use’ in this chapter). As long as it feels comfortable (not painful), increase the setting by one level within...

Este manual também é adequado para os modelos :
Secadores - SC2006/00 (2.85 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias