Log:
Assessments - 4, GPA: 3.3 ( )

Instruções de Operação GE, Modelo SEL-40-T1

Fabricante : GE
Arquivo Tamanho: 765.94 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. . . . . . . . . . . . . . . . . . . . . . . . . .2 13 1 2 3 4 5 6 7 2" TANGENT DRAW-OFF VALVE 1 2 3 4 5 6 7 2" TANGENT DRAW-OFF VALVE ITEM NO. PART NO. DESCRIPTION QTY. 1. - 7. KE50972-B DRAW-OFF ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. FA95049 WING NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE527551 KNOB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE52754 HEX NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 4. KE52753 RETAINER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 5. KE52752 PISTON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 6. FA00111 "O" RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 7. KE52751 VALVE BODY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 14 15 WARNING: Any maintenance or service involving disassembly of components should be made by a qualified service technician. Ensure electrical and water supply (if applicable) to the unit are shut off. ! LUBRICATION PROCEDURE Lubricate the following parts every three months to insure smooth operation and reduce wear. TRUNNION HOUSING, WORM SCREW AND TILT GEAR These parts are accessed through the top cover of the console. Apply grease to gear teeth. Check for excessive play and adjust with adjusting screw located on top of cross bar. Adjusting Screw Worm Screw and Tilt Gear Cross Bar TRUNNIONS On the left hand side of the skillet there are two grease nipples on the top back portion of the trunnion housing. On the right hand side of the kettle you must remove the console cover to access the two grease nipples. Trunnion Housing Grease Nipple HINGE ADJUSTMENT INSTRUCTIONS 1. FULLY LIFT COVER TO RELEASE SPRING TENSION SPRING 3. WHEN PROPERLY ADJUSTED, COVER SHOULD REST AT 70° 2. USING A 7/16" DEEP SOCKET ADJUST LEFT AND RIGHT BOLTS EVENLY MAINTENANCE 11. With the Tilt switch in the Down position SEQUENCE OF OPERATIONS When using these instructions refer to the SEL-TI wiring schematic. 1. Supply Voltage is sent to the primary of the 120 VAC transformer. 2. Supply voltage is sent to the normally open contacts of the Heat Contactors, C 1 and C2. 3. 120 VAC is sent from the secondary of the 120VAC transformer through the 3 amp fuse to ¦ The primary of the 24 VAC transformer . 24 VAC is sent from the secondary of the 24VAC transformer through the 1.25 amp fuse to the on/off switch. ¦ Contacts of the R1 Heat Relay 4. 120 VAC is sent from the secondary of the 120 VAC transformer to the optional Power Tilt Circuit (See step 9). 5. With the On/Off switch in the On position. ¦ 24 VAC is sent through the normally closed high limit switch to the mercury switch.. ¦ If the skillet is in the down position then 24 VAC is sent through mercury switch to pin 9 on the thermostat. 6. If the steamer is calling for heat the 24 VAC is sent from pin number 10 to RI Heat Relay. ¦ The normally open contacts of the Heat relay close sending 120 VAC to the Heat contactor coils C 1 and C2. 7. The Contactor close and supply Voltage is sent to the elements. ¦ The elements heat until the thermostat is satisfied. 8. When thermostat is satisfied, 24 VAC is removed from pin 10 on the thermostat and the heat circuit is de-energized. 9. If the skillet has the optional Power Tilt option and is in the down position, 120 VAC is sent from the secondary of the 120 VAC transformer through the circuit breaker and the up limit switch to the tilt switch. 10. With the tilt switch in switch in the Up position ¦ 120 VAC is sent to the Bridge Rectifier . 115 VDC is sent from the rectifier through the 30-ohm resistor to the normally open RY10 and RYI I relay contacts. ¦ 120 VAC is sent to the RY10 relay coil. ¦ The normally open RY10 contact close and 90 VDC is sent to the DC motor ¦ The DC motor is energized and the skillet tilts until the switch is released or the up limit switch opens. ¦ 120 VAC is sent to the Bridge Rectifier . 115 DC is sent from the rectifier through the 30-ohm resistor to the normally open RY 10 and RY 11 relay contacts. ¦ 120 VAC is sent to the RY11 relay coil. ¦ The normally open RY 11 contact close and the polarity of the 90 VDC is reversed. ¦ The DC motor is energized and the skillet lowers until the switch is released or POWER TILT MANUAL OVERRIDE In case of power failure or malfunction the skillet pan can be tilted manually following these instructions. MANUAL TILT SHAFT 10 MM 6 POINT SOCKET 1.Fit a 10 MM 6 POINT SOCKET over the MANUAL TILT SHAFT as shown above. 2.Turn socket wrench clockwise to empty contents. 16 SPARE PARTS LIST PART NO. DESCRIPTION ...

Este manual também é adequado para os modelos :
fritadeiras - SEL-30-T1 (765.94 kb)
fritadeiras - SEL-30-T1 (765.94 kb)
fritadeiras - SEL-30-T1 (765.94 kb)
fritadeiras - SEL-30-T1 (765.94 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias