Log:
Assessments - 1, GPA: 3 ( )

Instruções de Operação Buhler, Modelo 2335

Fabricante : Buhler
Arquivo Tamanho: 9.77 mb
Arquivo Nome : 3bdfca2f-1994-8064-c162-e6de09df6bdf.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The operator has the option of enabling the feature at any time. If the operator desires to enable the external automatic shutdown feature, proceed as follows: 1. Unhook the battery cables from the batteries. This will prevent any possibility of an accidental short while making the conversion. See Section 3 in this manual for information on how to disconnect the cables. NOTE: Disconnecting the batteries will not remove any calibration numbers from the memory of the Electronic Instrument Control System. If the tractor is equipped with the optional Tractor Performance Monitor (TPM), the TPM may have to be reset. 2-96 SECTION 2 -OPERATION 2. Locate the two-terminal bus bar, 1, on the right side of the electronic control panel. 1 3. Attach the wire leading out to the external source to the right terminal of the bus bar, 1, (the terminal is marked “Shutdown External”). 4. Route the wire out to the external source through the cover plate at the right rear corner of the cab. See “Installation of Cab-Mounted Accessories” for correct wire routing. 5. The external end of the wire must be hooked to a grounded sending unit of some type to provide a ground source for the Electronic Instrument Control System. An example of this would be an oil pressure sending unit or a coolant temperature sending unit on an external engine. NOTE: Any type of external grounding source will work, but there must be a good ground connection between the towed implement and the tractor frame. Just using the drawbar pin may not be adequate, and a safety chain is suggested for additional ground contact. 6. Reinstall the cover onto the electrical control panel. 7. Reconnect the battery cables. To disable the shutdown feature, follow this procedure in reverse order. 1 Figure 2-129 Figure 2-130 2-97 SECTION 2 -OPERATION External Alarm Control Conversion -Each tractor is manufactured so that the Electronic Instrument Control System can be converted to inform the operator, via the electronic monitor and audible alarm, that there is a problem with an outside source (i.e., a towed implement that is powered by a separate engine). If the tractor Electronic Instrument Control System receives a signal from an external source, the upper portion of the electronic monitor will flash “EXT” “ALR”. The audible alarm will beep rapidly. The lower portion of the monitor will continue to display whatever is selected on the rotary select switch. The operator can cancel the audible alarm and the “EXT” “ALR” display by pressing the acknowledge/reset button. The audible alarm and display will return if the external signal is received by the monitor again. NOTE: On tractors equipped with a Tractor Performance Monitor (TPM), the external alarm feature will activate when the “% slip” or “Time of Day” alarm settings are reached. See the TPM operation section of this manual for further information. When the external audible alarm control is enabled and a signal is received by the Electronic Instrument Control System from an outside source, the automatic shutdown feature will not be engaged. Tractors are assembled with the external alarm control feature disabled. The operator has the option of enabling the feature at any time. If the operator desires to enable the external alarm control feature, proceed as follows: 1. Unhook the battery cables from the batteries. This will prevent any possibility of an accidental short while making the conversion. See Section 3 for information on how to disconnect the cables. NOTE: Disconnecting the batteries will not remove any calibration numbers from the memory of the Electronic Instrument Control System. If the tractor is equipped with the optional Tractor Performance Monitor (TPM), the TPM may have to be reset. Figure2-131 2-98 SECTION 2 -OPERATION 2. Locate the two-terminal bus bar on the right side of the electronic control panel. 1 3. Attach the wire leading out to the external source to the left terminal of the bus bar, 1, (the terminal is marked “Audio External”). 4. Route the wire out to the external source through the cover plate at the right rear corner of the cab (See “Installation of Cab-Mounted Accessories” in Section 1 for correct wire routing). 5. The external end of the wire must be hooked to a grounded sending unit of some type to provide a ground source for the Electronic Instrument Control System. An example of this would be an oil pressure sending unit or a coolant temperature sending unit on an external engine. NOTE: Any type of external grounding source will work, but there must be a good ground connection between the towed implement and the tractor frame. Just using the drawbar pin may not be adequate, and a safety chain is suggested for additional ground contact. 6. Reinstall the cover onto the electrical control panel. 7. Reconnect the battery cables. To disable the shutdown feature, follow this procedure in reverse order. NOTE: There is a secondary source for connecting an external signal to the external alarm co...

Este manual também é adequado para os modelos :
Cortadores de grama - 2290 (9.77 mb)
Cortadores de grama - 2360 (9.77 mb)
Cortadores de grama - 2375 (9.77 mb)
Cortadores de grama - 2425 (9.77 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias