Log:
Assessments - 5, GPA: 4.4 ( )

Instruções de Operação Empire Comfort Systems, Modelo PAE

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 2.95 mb
Arquivo Nome :
Língua de Ensino:
Ir para baixar



Facilidade de uso


Power Code 01 - Complete Power Code descriptions 02 - are shown on pages 18 and 19 of this manual etc. Ignition Type C – Standing Pilot G – Intermittent Pilot K – Intermittent Pilot Heat Exchanger A - Aluminized S - Stainless Steel RATING PLATE IDENTIFICATION MODEL IDENTIFICATION PLATE SERIAL NUMBER MODEL NUMBER POWER CODE CONTROL CODE 01121010692 PD150AE 01 30 Serial Number Designations 01 12 101 10 95 MOTOR VENDOR CODE 01 - Century 05 - Universal etc. SERIES IDENTITY NUMBER Identifies which series of controls were furnished on the unit. FAN OR BLOWER VENDOR CODE 01 - Revcor 08 - Brookside etc. YEAR OF MANUFACTURE 91 - 1991 92 - 1992 etc. WEEK OF MANUFACTURE 10 - 10th week of 1995 25 - 25th week of 1995 etc. Heater Parts from ACF Greenhouses 27 CONTROL OPTIONS Propeller and Blower Unit Heaters – PAE and BAE Models % ! Single-Stage, Standing Pilot, 100% Shut-Off – Utilizes a single-stage combination gas control and thermocouple. Pilot needs to be manually lit initially and stays lit. Two-Stage, Standing Pilot, 100% Shut-Off – Utilizes a two-stage gas control (which fires at 50% or 100% of full rated input) and thermocouple. Pilot needs to be manually lit initially and stays lit. Available on PAE/BAE models only. Single-Stage, Intermittent Pilot Ignition, 100% Shut-Off with Continuous Retry – Utilizes a singlestage combination gas control and an ignition control (continuous retry). Pilot is automatically lit on call for heat. Mechanical Modulation with Automatic Pilot Ignition, 100% Shut-Off with Continuous Retry – Utilizes a modulating combination gas control and an ignition control (continuous retry). Pilot is automatically lit whenever there is power to the unit. Modulation range is between 50% and 100% fire; gas control shuts off below 50% fire. Available on BAE models only. Two-Stage, Intermittent Pilot Ignition, 100% Shut-Off with Continuous Retry – Utilizes a two-stage combination gas control (which fires at 50% or 100% of full rated input) and an ignition control (continuous retry). Pilot is automatically lit only on call for heat. Available on PAE/BAE models only. 11 12 81 82 25 26 83 84 30 31 85 86 59 60 89 90 63 64 87 88 115V 200/230V 115V 200/230V 115V 200/230V 115V 200/230V 115V 200/230V 115V 200/230V 115V 200/230V 115V 200/230V 115V 200/230V 115V 200/230V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V 24V natural natural propane propane natural natural propane propane natural natural propane propane natural natural propane propane natural natural propane propane Control System Description Control Code No. Service Voltage Thermostat Voltage Type of Gas % Models BAE 50 thru BAE 100 with two-stage or modulating gas controls require a Category II vent system. For units with control systems having fan timer, fan starts 30 seconds (max.) after ignition and shuts down approximately 60 seconds after main bu...

Este manual também é adequado para os modelos :
Aquecedores a gás - BAE (2.95 mb)
Aquecedores a gás - BAE (2.95 mb)
Aquecedores a gás - BAE (2.95 mb)
Aquecedores a gás - BAE (2.95 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias