Log:
Assessments - 5, GPA: 4.4 ( )

Instruções de Operação Empire Comfort Systems, Modelo LS-30FAO-1

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 422.53 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


4 LS-18FA(C,O,S)-1 Photos ............................................................................................................................. 5 LS-24FA(C,O,S)-1 Photos ............................................................................................................................. 6 LS-30FA(C,O,S)-1 Photos ............................................................................................................................. 7 Parts List & Parts View .................................................................................................................................. 8 How to Order Repair Parts ............................................................................................................................. 8 Page 2 15997-0-0903 IMPORTANT INSTALLATION GUIDELINES IMPORTANT INSTALLATION GUIDELINES Proper Log Placement Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs. Logs must fit firmly onto the burner when positioned as shown in the photos. Misformed logs or logs with sloppy pin holes must be replaced. Proper Placement of Rock Wool and Decorative Lava Rock Rock wool can be added to burners for a glowing ember effect. It must be positioned only on the front portion of the burner. The photos in this manual show the proper placement of rock wool. Decorative lava rock or small wood pieces should never be placed on the burner. These items are only for placement on the floor of the fireplace or firebox. Proper Primary Airflow into Burner For proper burner operation and flame appearance, the flow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This flow of air is reduced if dirt, lint or other obstructions build-up around or inside the venturi. Any obstruction in the venturi tube area must be removed. The flow of air into the venturi is also reduced if the gas orifice isn’t centered in the venturi inlet and/or is not aligned with the venturi. Any misalignment of the burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube. Ceiling Fans, Portable Fans or Logs Installed Near Cold Air Returns Ceiling fans or oscillating floor type fans need to be monitored during the operation of vent-free logs. If the air blows directly into the flame causing it to impinge on the log set, or firebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate flame impingement, and the floor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around a vent-free log set can cause the flame to impinge on the log and create a sooting situation. WARNING: Do not allow fans to blow directly into the ...

Este manual também é adequado para os modelos :
Aquecedores a gás - LS-18FAC-1 (422.53 kb)
Aquecedores a gás - LS-18FAS-1 (422.53 kb)
Aquecedores a gás - LS-24FAC-1 (422.53 kb)
Aquecedores a gás - LS-24FAO-1 (422.53 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias