Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Lifebreath, Modelo 1200DD

Fabricante : Lifebreath
Arquivo Tamanho: 1.4 mb
Arquivo Nome : 7ac28269-e57f-454f-a836-edc794eb8101.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


During the winter months the incoming cold fresh air is warmed by utilizing the heat recovered from the stale air before it is exhausted to the outdoors. During summer months when the indoor space is air conditioned, the Heat Recovery Ventilator will help in cooling the incoming fresh air with the stale air that is being exhausted. For Technical and Application Information Call NUTECH Service Dept. 519-457-1904 TABLE OF CONTENTS Engineering Data.......................................................2 Defrost.......................................................................2 Location for Mounting the HRV.................................3 The Ductwork System ..............................................4 A. Outside Weatherhoods..............................4 B. Ducting from Hoods ..................................4 Warmside Ducting General-......................................4 Stale Air Return System............................................5 Fresh Air Supply System...........................................5 Integrated HVAC System..........................................6 Electrical Connections...............................................6 Air Flow Balancing.....................................................6 Integrated HVAC System Illustrations........................7 Installation Types......................................................8 Performance Charts.................................................9 Dimensions..............................................................10 HEAT RECOVERY VENTILATORS (HRVs) 1 ENGINEERING DATA CORES Engineered with aluminum for superior thermal conductivity, meets the flame spread and smokq developed classifications of the National Building Code and NFPA 90A (1993 Edition). MODEL 700FD, 700DD, 900FD, 900DD - Dual Cores MODEL 1200FD, 1200DD - Triple Cores MOTORS Two PSC, 3 speed - Models 700 & 1200 Two PSC, 5 speed - Model 900 MODEL 700 -single shafted, 120VAC, 2.75 Amps each-(5.50 TOTAL on HIGH speed), HP 1/5-1/8- 1/10,1625 RPM. Watts -Total high speed - 648 MODEL 900 -double shafted, 120VAC, 3.15 Amps each-(6.3 TOTAL on HIGH speed), HP 1/0, 1625 RPM. Watts -Total high speed - 610 MODEL i200-double shafted, 120VAC, 3.8-2.8-2.1 Amps-(7.60 TOTAL on HIGH speed), HP 1/4-1/5-1/6,1625 RPM.Watts -Total high speed - 912 FILTERS Washable air filters in exhaust and supply air streams. BLOWERS Centrifugal type MODEL 700 400-700 CFM (188 - 329 L/s) Typical Air Delivery. Each air stream has 1 single shafted motor driving 1 centrifugal blower. MODEL 900 500-900 CFM (235 - 423 L/s) Typical Air Delivery. Each air stream has 1 double shafted motor driving 2 centrifugal blowers. MODEL 1200 800-1200 CFM (378 - 566L/S) Typical Air Delivery. Each air stream has 1 double shafted motor driving 2 centrifugal blowers. CONNECTION DUCT SIZES MODELS 700 & 900 Four (4) - 8” X 14" (200 X 356 mm) MODEL 1200 Four (4) - 8" X 20" (200 X 508 mm) UNIT DIMENSIONS MODELS 700 & 900 Length 28 3/8" (720 mm) Width 29 5/8" (753 mm) Height 24 5/8" (625 mm) Weight 133 lbs. (60.45 kg) MODEL 1200 Length 41 1/2" (1055 mm) Width 29 7/8" (760 mm) Height 24 5/8" (625 mm) Weight 184 lbs. (83.6 kg) MOUNTING Eight (8) -10/24" (10.5 mm) threaded inserts at corners of case (2 for each support strap) Four (4) - Polyester reinforced PVC support straps CASE 20 gauge prepainted galvanized steel (G 60) for superior corrosion resistance. Insulated with a foil faced fibreglass duct liner where required to prevent exterior condensation. DRAIN CONNECTIONS 2 -1/2" ( 12mm) OD connections. CODES and STANDARDS CSA approved. All components are UL listed. CONTROLS • Lighted power switch • 3 speed blower control -models 700, 1200 • 5 speed blower control -model 900 • Defrost light indicates when defrost occurs. This is automatic when outside condition drops below 23‘F (-5*C) • Low voltage (24 VAC) strip for external fan speed override to "HIGH" FAN DEFROST The Models 700FD, 900FD and 1200FD are equipped with an electronically controlled fan defrost system to remove frost that collects on the warm air side of the aluminum heat transfer surfaces of the heat exchanger core. When the outside air temperature drops below 23'F (-5°C), a defrost timer is activated which provides for an automatic defrost cycle every 17 minutes. During the automatic defrost cycle the fresh air supply is shut off for approximately 4.5 minutes while the exhaust fan continues to operate. This allows warm inside air to flow over the heat exchanger core melting any frost accumulation. After the defrost period, the fresh air supply fan automatically returns to the normal speed and fresh outside air continues to be drawn into the bu...

Este manual também é adequado para os modelos :
As consolas de jogos - 1200FD (1.4 mb)
As consolas de jogos - 700DD (1.4 mb)
As consolas de jogos - 700FD (1.4 mb)
As consolas de jogos - 900DD (1.4 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias