In shutdown mode the UPS stops supplying power to the load. The online and overload LED indicators flash alternately or, if the UPS has shutdown due to a low battery, the UPS will beep once every 4 seconds for approximately 16 seconds. When line power is restored, the UPS will return to on-line operation. Cold Start Note: Cold start is not a normal operating condition. When the UPS is “Off” and there is no utility power, it is possible to cold start the UPS to power the loads from the UPS battery. • Press and hold the On/Off/Test button until the UPS begins beeping. • Release the On/Off/Test button during the beeping to start the UPS. APC, Back-UPS Pro, and PowerChute are registered trademarks of American Power Conversion Corp. All other trademarks are the property of their respective owner. Copyright © 2003 Storage Storage conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least 4 hours. Extended storage At -15 to +30 °C (+5 to +86° F), charge the UPS battery every 6 months At +30 to +45 °C (+86 to +113° F), charge the UPS battery every 3 months. Repplaacciingg the BBatttteryy TTrroouubblleesshhoooottiinngg This UPS has an easy to replace hot-swappable battery. Battery replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and loads on for the following procedure. See your dealer or call the number in this manual for information on replacement battery kits. Note: Once the battery is disconnected, the loads are not protected from power outages. 1. Grasp the top of the front cover and tilt it out and down. 2. Unhook the bottom of the cover from the chassis and lift it upward to expose the battery door. Be careful not to strain the ribbon cable. Do not touch the exposed printed circuit board. 3. Fold the front cover on top of the UPS as shown. 4. Use a flat-blade screwdriver or a coin to remove the two battery door screws and open the door. 5. Grasp the tab and gently pull the battery out of the UPS. 6. Disconnect the battery leads. • For the 1000/1050/1100 VA models, loosen the connectors by gently wiggling them while pulling straight back from the battery connector. 1000-1100 VA • For the 1400 VA model, pull the two gray couplers apart to disconnect the battery. 7. Connect the battery leads to the new battery. Note: Small sparks at the battery connectors are normal during 1400 VA connection. • For the 1000/1050/1100 VA models, connect the red wire to the positive (+) terminal and the black wire to the negative (–) terminal. • For the 1400 VA model, connect the gray battery coupler to the UPS coupler. 8. Slide the battery into the UPS. 9. Close the battery door, replace the battery compartment screws, and replace the front cover. 10. Dispose of the old battery properly at an appropriate recycling facility or return it to the supplier in the packing material for the new battery. See the new battery instructions for more information. Warranty Customers may return their defective unit to APC for replacement or repair during the standard 2-year warranty period. APC's standard procedure will be to replace the original unit with a factory-reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Customer Service. APC will ship the replacement unit once the defective one has been received by the repair department. The customer pays for the shipping to APC, APC covers ground freight transportation costs back to the cust...
Este manual também é adequado para os modelos :Fonte de alimentação e fonte de alimentação - 1050 (267.54 kb)
Fonte de alimentação e fonte de alimentação - 1400 (267.54 kb)
Fonte de alimentação e fonte de alimentação - 1000 (267.54 kb)