Facilidade de uso
When line power is requalified, the Pinnacle automatically restarts, providing power to the loads and recharging the batteries. • RS.232 Communication The Pinnacle Plus series can be remotely monitored and controlled. • LCD/LED Display Panel The LCD/LED display provides .at-a-glance. monitoring. • Battery Charge Display The LCD shows the battery % charge, battery backup time and battery voltage. • Load Display The LCD shows the unit.s % loading and the loading in watts and VA. • Automatic Bypass When the Pinnacle Plus detects an internal fault such as deep battery discharge or an overload, it automatically uses its built-in bypass circuit to switch the load to line power. • Fully Digitized Microprocessor Controlled Pure sine wave output with less than 3% THD. • Cold Start If there is no line at the input, the Pinnacle automatically provides battery power to the load. • Load Shedding The power management software allows less important equipment to be turned off during power outages to save battery power for the critical loads. Alpha Technologies 3 1 Introduction 1.2 Unpacking and Inspection Checklist TIP: If items are missing or damaged, contact Alpha and the shipping company at once. Most shippers have a short claim period. Carefully remove the unit from its shipping container. Inspect it for damage and make sure the following items are included: One Pinnacle Plus series UPS with pre-installed batteries. One operator.s manual. One power cord. One Alphamon CD-ROM. One RS.232C interface cable. Any ordered options. Save The Original Shipping Container If you need to return the unit for servicing, pack it in the original shipping container. Alpha is not responsible for damage caused by the improper packaging of returned units. Read This Manual Before installation, become familiar with your unit by reviewing the procedures and drawings in this manual. If you have any questions about the safe installation, operation or maintenance of the unit, contact Alpha.s customer service department. Alpha Technologies 1 Introduction 4 1.2 Unpacking and Inspection Checklist (Continued) For technical support contact Alpha Technologies customer service department directly at: United States: (360) 647-2360 Germany: +49-9122-79889-0 Canada: (604) 430-1476 Middle East: +357-253-75675 United Kingdom: +44-1279-501110 Australia: +61-2-9722-3320 For emergency technical support 7 days a week / 24 hours a day call: USA: 1–800–863–3364 CANADA: 1–800–667–8743 Complete the following for your records Serial # __________________________________ Options __________________________________ Purchase Date ____________________________ This Pinnacle Plus was purchased from Dealer ___________________________________ City _____________________________________ State/Province _____________________________ Zip/Postal Code ___________________________ Country __________________________________ Telephone # _______________________________ Fax # ____________________________________ E Mail ___________________________________ Alpha Technologies 5 1 Introduction 1.3 The Pinnacle Plus Series 1.3.1 Front Panel These drawings are used for illustrative purposes only. See your unit for the exact location and type of all switches and controls. The batteries are reached through this panel. The control panel.s operation is described in Section 3.2. Tower Mount Control Panel ON-LINE ON ON-BATT BYPASS FAULT ON/OFF FUNC ENTER Cooling Vents(Must not be blocked) Rack Mount Control Panel ON-LINE ON ON-BATT BYPASS FAULT ON/OFF FUNC ENTER Removable Battery Cover Cooling Vents (Must not be blocked) Alpha Technologies 1 Introduction 6 Alpha Technologies 1.3 The Pinnacle Plus Series (Continued) 1.3.2 Rear Panel These drawings are used for illustrative purposes only. See your unit for the exact location and type of all connectors, switches and circuit breakers. Tower Mount Optional Interface Optional External Battery Connector Optional USB Port Outlets EPO RS-232 Network Transient Protector Input Power Connector Input Circuit Breaker Cooling Output Fans Circuit Breakers Figure 1.2 2KVA.3KVA Optional Interface EPO RS-232 Optional External Battery Connector Optional USB Port Outlets Network Transient Protector Input Power Connector Input Circuit Breaker Cooling Fan Figure 1.1 700VA/1KVA/1.5KVA 7 1 Introduction Alpha Technologies 1.3 The Pinnacle Plus Series (Continued) Rack Mount Figure 1.3 700VA/1K/1.5KVA Input Circuit Breaker EPO RS-232 Optional Interface Outlets Optional Input USB Port Optional External Battery Connector Cooling Fan Network Transient Protector Figure 1.4 2KVA.3KVA Input Circuit Breaker EPO RS-232 Optional Interface Outlets Optional USB Port Input Optional External Battery Connector Cooling Fans Network Transient Protector 1 Introduction 8 1.3 The Pinnacle Plus Series (Continued) 1.3.3 Available Output Connectors Multiple configurations are available from the factory for various requirements. AMERICAN IEC GERMAN BRITISH FRENCH AUSTRALIAN Figure 1.5 Output Connecto...
Este manual também é adequado para os modelos :Fonte de alimentação e fonte de alimentação - 1000 (1023.25 kb)
Fonte de alimentação e fonte de alimentação - 2000 (1023.25 kb)
Fonte de alimentação e fonte de alimentação - 3000 (1023.25 kb)
Fonte de alimentação e fonte de alimentação - 700 (1023.25 kb)