Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Graco Inc., Modelo Husky 239090

Fabricante : Graco Inc.
Arquivo Tamanho: 284.6 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Minimum and Maximum Operating Temperatures Find the minimum and maximum operating temperatures for your surge suppressor unit in the list below. These temperature limits are stated at zero gauge pressure. Automatic Husky 750 239095 10 to 180 F (–12 to 82 C) 239096 32 to 175 F (0 to 79 C) 239121 40 to 175 F (4 to 79 C) 239122 32 to 175 F (0 to 79 C) 239123 40 to 220 F (4 to 104 C) 239124 –10 to 350 F (–23 to 176 C) Automatic Husky 2000 239092 32 to 175 F (0 to 79 C) 239093 32 to 175 F (0 to 79 C) 239126 40 to 175 F (4 to 79 C) 239127 32 to 175 F (0 to 79 C) 239128 40 to 175 F (4 to 79 C) Manual Husky 750 239090 10 to 180 F (–12 to 82 C) 239091 32 to 175 F (0 to 79 C) 239129 40 to 175 F (4 to 79 C) 239130 32 to 175 F (0 to 79 C) 239131 40 to 220 F (4 to 104 C) 239132 –10 to 350 F (–23 to 176 C) Manual Husky 2000 239087 32 to 175 F (0 to 79 C) 239088 32 to 175 F (0 to 79 C) 239134 40 to 175 F (4 to 79 C) 239135 32 to 175 F (0 to 79 C) 239136 40 to 175 F (4 to 79 C) . . Operation Charging and Startup For optimum performance, surge suppressors should be charged to a pressure 2 to 10 psi (0.01 to 0.07 MPa, 0.1 to 0.7 bar) lower than system pressure. Automatic Models CAUTION Automatic surge suppressors must have the air supply connected before you start pumping. Failure to do so could result in the internal air valve puncturing or rupturing the bladder. The air pressure gauge (1) (See Parts Drawings on pages 14 and 15) on automatic surge suppressors remains at zero pressure even after the air line is connected, because the surge suppressor only allows air into the air chamber when it is required to dampen pulsation. After the air supply line is attached to the one-way check valve (8) and air is available, you can start the pump. No further adjustments are necessary. NOTE: Automatic surge suppressors are not recommended for use as suction stabilizers at the pump inlet or as a surge suppressor at a quick-closing valve. Adjustable surge suppressors should be used for such applications. Manual Models CAUTION Manual surge suppressors must be charged before you start pumping. Failure to do so could result in the internal air valve puncturing or rupturing the bladder. Before you start the pump, charge the surge suppressor with air line pressure. 1. Start the pump to generate system pressure. 2. As pressure increases to approach working pressure, gradually decrease the regulated air supply pressure into the surge suppressor by adjusting the regulator (4) (See Parts Drawings on pages 14 and 15). 3. Wait for up to one minute to allow the system to respond to the adjustment before you make any further adjustments. Generally, pulsation is most effectively minimized when the air supply to the surge suppressor is regulated to 2 to 10 psi (0.01 to 0.07 MPa, 0.1 to 0.7 bar) lower than system pressure. . . Troubleshooting WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. R...

Este manual também é adequado para os modelos :
Fonte de alimentação e fonte de alimentação - Husky 239121 (284.6 kb)
Fonte de alimentação e fonte de alimentação - Husky 2000 (284.6 kb)
Fonte de alimentação e fonte de alimentação - Husky 239135 (284.6 kb)
Fonte de alimentação e fonte de alimentação - Husky 239136 (284.6 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias