Fabricante : Allied Telesis
Arquivo Tamanho: 362.91 kb
Arquivo Nome : pwr3202_ig_b.pdf
|
Facilidade de uso
The RPS can supply power to Allied Telesis switches if the switch’s main power supply fails. Verifying Package Contents Verify that the correct components are included in your package: • AT-PWR3202 Power Supply • One 21-pin D-combo connector cable • This installation guide If any item is missing or damaged, contact your Allied Telesis sales representative for assistance. Warranty The AT-PWR3202 Power Supply has a Lifetime Year Warranty (Five Years Power Supply and Fan). For detailed warranty information, see the website. Installing the Power Supply To install an AT-PWR3202 Power Supply, perform the following procedure: 1. Remove the AT-PWR3202 unit from its shipping package and store the package in a safe place. You must use the original package if you need to return the power supply to Allied Telesis. 2. On the back of the AT-RPS3204 unit, locate the power switch that corresponds to the slot where you are going to install the power supply and verify that the On/Off button is in the Off (out) position. From left to right on the back, the power supplies are identified as B2, B1, A2, A1. (An ATRPS3204 is shipped with one AT-PWR3202 in the slot marked A1.) 3. Using a Phillips head screwdriver, remove the cover from the slot in the front of the AT-RPS3204 unit where you want to install the power supply. Note As an example, the following steps show an AT-PWR3202 unit installed in slot A2 of the AT-RPS3204 Redundant Power Supply. Keep the slot cover in a safe area in case you remove a power supply. The slot cover helps maintain proper air flow through the RPS. 4. Slide the AT-PWR3202 Power Supply into the slot 5. Use a Phillips head screwdriver to tighten the captive screws. 6. On the back of the AT-RPS3204 unit, plug one end of the 21-pin D-combo connector cable into the connector that corresponds to the slot in which you installed the AT-RPS3202 Power Supply. 7. Tighten the captive screws. 892 STATUS POWER FAULT AT-PWR3202 12VDC ,16.6A MAX STATUS POWER FAULT 893 AT-PWR3202 12VDC ,16.6A MAX STATUS POWER FAULT 894 STATUS POWER FAULT AT-PWR3202 12VDC ,16.6A MAX AT-PWR3202 12VDC ,16.6A MAX STATUS POWER FAULT 895 STATUS POWER FAULT AT-PWR3202 12VDC ,16.6A MAX AT-PWR3202 12VDC ,16.6A MAX 198 RPS OUTPUT A2 12VDC RPS OUTPUT A1 12VDC AC INPUT A2/A1 100 - 240 VAC ~ ON OFF ON OFF A1 A2 199 RPS OUTPUT A2 12VDC RPS OUTPUT A1 12VDC AC INPUT A2/A1 100 - 240 VAC ~ ON OFF ON OFF A1 A2 4 5 6 8. Plug the other end of the cable into the connector labeled “RPS INPUT” on the back of an Allied Telesis switch. 9. Tighten the captive screws. 10. Press the On/Off switch for that power supply to move it to the On (in) position. Note An AT-PWR3202 Power Supply is NOT hot-swappable into and out of the AT-RPS3204 Redundant Power Supply. To replace an AT-PWR3202 unit, first turn the power off using the appropriate On/Off switch and then remove and replace the power supply. To remove the connector cable, turn the power off first using the appropriate On/Off switch. LEDs The power supply has one LED, labeled Status. The RPS LED on the front of the Allied Telesis switch should be green. For more information about the RPS LED, refer to the installation guide that is shipped with your Allied Telesis switch. Specifications Electrical, Safety, and Emissions Statements This product meets the following standards. RFI Emissions EN 55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A RFI Emissions EN 55022 Class A IImmunity EN 55024 Electrical Safety UL 60950 (CULUS), EN 60950 (TUV) Copyright © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. RPS INPUT 400 RPS INPUT 401 402 RPS OUTPUT A2 12VDC RPS OUTPUT A1 12VDC AC INPUT A2/A1 100 - 240 VAC ~ ON OFF ON OFF A1 A2 Color Description Amber Indicates a fault. The power supply may be faulty, or the power supply is functioning properly but is not correctly connected to an Allied Telesis switch. Green The power supply is connected to an Allied Telesis switch and is functioning normally. Item Specification Dimensions (H x W x D) 41.1 x 109 x 248.7 mm (1.62 x 4.29 x 9.79 in.) Operating Temperature 0° C to 40° C Storage Temperature -20° C to 80° C Relative Humidity <85% noncondensing Supply Voltage 12 V U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to co...