Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Bayer HealthCare, Modelo Ascensia Elite XL

Fabricante : Bayer HealthCare
Arquivo Tamanho: 1.72 mb
Arquivo Nome : 4b5c99d5-6efd-f674-f98e-90c204452fa7.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Insert into Meter before drawing in blood or control sample. • Ascensia ELITE™ Check Strip – use to check if the Meter is working properly before running a blood glucose test. • Ascensia ELITE™ Code Strip – use to set the Meter (calibrate) to match the box of Test Strips. • MICROLET® Adjustable Lancing Device – use for finger puncture with a MICROLET® Lancet. • NORMAL CONTROL SOLUTION – use to confirm system is working correctly. • BATTERIES – replace when necessary. The Ascensia ELITE™ XLDiabetes Care System is a blood glucose monitoring system for diabetes management in home or professional use. The system is based on electrode sensor technology. Convenient features of the system are: • Two-step testing process: 1. Insert Test Strip in Meter 2. Touch TEST END to blood • Test results are displayed in 30 seconds. • Meter turns on when inserting a strip and turns off when removing the strip. • Up to 120 test results may be stored in the Meter and can be recalled when necessary. • Stored results may be transferred to a computer and analyzed with WinGlucofacts™ XL software. • Agrees with laboratory serum/ plasma glucose results (values 10–15% higher than whole blood glucose results). Automatic Strip-filling Action • Capillary action at the end of the Test Strip automatically draws a small amount of blood into the reaction chamber. Frequently Asked Questions 2 What do I do first? If needed, install batteries and set the time—test the Meter electronics with a Check Strip—code the Meter to match Ascensia ELITETest Strips—and then run a control test to test the whole system before running a blood glucose test. What does blood glucose monitoring do for me? Blood glucose levels change during the day due to medication, exercise, diet, insulins or hypoglycemics (oral agents) or possibly stress and illness. Blood glucose testing provides information that will help you understand the changes. This information can help you manage your diabetes to keep your blood sugar levels within your target range. Do I need to read this book? This instruction guide is provided as a reference as you operate the system. It is important for you to read through the User Guide to understand how the whole system operates and what information is available for your needs. For short simple instructions, a quick reference guide is also provided for your convenience with procedures and information most often needed. It can be useful when traveling. If you have any concerns or questions as you learn how to use the system, please call our Customer Service Dept. 1-800-348-8100 or visit our website at or 2 Important Information • The Ascensia ELITE™ XLBlood Glucose Meter has been designed for use with Ascensia ELITE™ Test Strips. The performance characteristics of the Meter may not be valid for any other brand of Test Strips. The use of other Test Strips may cause erroneous results. Bayer Corporation does not warrant the use of the Ascensia ELITE XLBlood Glucose Meter with any Test Strip other than Ascensia ELITE Test Strips. • Glucose levels below 50 or above 250 mg/dL (below 2.8 or above 13.9 mmol/L) may indicate a potentially serious medical condition. If your glucose is below 50 mg/dL or above 250 mg/dL, contact your healthcare professional immediately. CAUTION: Before using any product to test your blood glucose (sugar), read all instructions and practice the test. Do all quality control checks as directed and consult with a diabetes health professional. These recommendations apply to all blood glucose monitoring systems and are supported by the American Association of Diabetes Educators,* the American Diabetes Association, the Food and Drug Administration and Health Industry Manufacturers Association. *You may call the American Association of Diabetes Educators for the location of a Certified Diabetes Educator (CDE) near you 1-800-338-DMED. User Guide Contents 2 SECTION PAGE Set Up For Testing 1 Install Batteries 4 2 Set the Alarm, Time and Units 5 3 Check Strip Test 6 4 Code the Meter 7 5 Control Test 8 Testing 6 Blood Glucose Test 11 7 Important to Remember 15 Test Result Management 8 Stored Test Results 17 9 Data Management 18 Taking Care 10 Meter and Test Strip Care 19 11 Meter and Test Strip Problems 21 Technical Support Information 12 Service 25 13 Limitations of the Procedure 27 14 Specifications 28 15 Supplies 29 16 Warranty 31 SECTION1Install Batteries SECTION1Install Batteries Install batteries when the Meter is new if needed. Replace batteries when the Meter displays the battery symbol . 1. Press firmly on “open” arrow and slide forward in the direction of the arrow. The lid releases. 2. Place new batteries into the battery compartment with the “+” side up. Slide lid back into place, lining up with open slots, and close firmly. Test results stored in the memory are not erased when batteries are changed, but time must be reset. NOTE: Two 3 volt (CR2032) lithium batteries are furnished with t...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias