Log:
Assessments - 5, GPA: 4.2 ( )

Instruções de Operação Lincoln, Modelo 1116-080-A

Fabricante : Lincoln
Arquivo Tamanho: 1.17 mb
Arquivo Nome : 7afaf09e-9214-4910-bb01-45022ef6dd3a.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


GAS 120VAC 60 HZ. 1 PHASE MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A LP GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A1 LP GAS 120VAC 60 HZ. 1 PHASE POWER SUPPLY Electrical power is supplied to the oven by a three-conductor cordset. Voltage from the black conductor to the white conductor is 120VAC. Black conductor is hot White conductor is neutral. Green conductor is ground. CONTROL BOX AUTO When the temperature in the control box reaches 120°F ± 3° (48.9°C ± 1.7°), theCOOL DOWN cooling fan thermostat will switch power to the control box cooling fans. The thermostat will interrupt power to the cooling fans when the control box temperature falls to 100°F ± 3° (37.8°C ± 1.7°). MAIN FAN CIRCUIT Power is permanently supplied, through a 10 amp fuse, to the normally open main power switch. Power is also supplied to the normally open cooling fan thermostat. Closing the main power switch supplies 120VAC to the main fan motor, the cooling fan motors, the primary of the control transformer, the conveyor motor and to the ignition control. BURNER CIRCUIT Closing the main power switch supplies 120VAC to the burner blower motor. 120VAC is also supplied, through the main fan centrifugal switch (this switch closes when the main fan reaches approx. 1600 RPM) and the normally closed oven cavity hi-limit thermostat, to the primary of the burner transformer. 120VAC is also supplied to the oven control. IGNITION CONTROL The ignition control operates on both 24VAC and 120VAC. When the control is energized by 24VAC from the transformer, 120VAC is switched by the ignition control to the hot surface igniter for 45 seconds for the hot surface igniter warm up. The igniter glows red, 24VAC is switched to the gas valve, which opens, and ignition should now occur. TEMPERATURE CONTROL Closing the main power switch supplies 120VAC to the primary of the oven control transformer. Secondary voltage, 24VAC, is supplied to the oven control. The oven control is set to desired temperature. The thermocouple will provide varying millivolts to the oven control. The oven control supplies 120VAC to the temperature regulation valve at intermittent intervals to maintain the desired temperature. The display on the oven control will indicate when the temperature regulation valve is energized. NOTE: The display also indicates oven temperature. CONVEYOR DRIVE Closing the main power switch supplies 120VAC to the conveyor motor and to the primary of the control transformer. Secondary voltage, 24VAC, is supplied to the oven control. Setting the oven control to the desired time outputs voltage, through a reversing switch, to the conveyor motor. NOTE: The conveyor system uses a hall effect sensor and magnet to prove operation of the conveyor motor. If the conveyor motor is not running, “BELT JAM” is indicated on the display. Impinger II – Advantage Digital Express Service Manual - Domestic SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, ELECTRIC (OVENS WITH PUSH BUTTON CONTROLS) 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240V...

Este manual também é adequado para os modelos :
Fornos Elétricos - 1116-080-A1 (1.17 mb)
Fornos Elétricos - 1117-080-A (1.17 mb)
Fornos Elétricos - 1117-080-A1 (1.17 mb)
Fornos Elétricos - 1130-080-A (1.17 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias