Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Garland, Modelo 6

Fabricante : Garland
Arquivo Tamanho: 227.64 kb
Arquivo Nome : i-Installation.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Operational water pressure: MIN: 30 psi (200kPa) MAX: 88 psi (600kPa). RECOMMENDED: 44 psi (300kPa). Water flow must be at least 3 gal/min (12 l/min). Water connection supplied by customer: 1.2 in. pressure hose with R 3.4 in. tapered fitting. Customer fitted shut-off valve for each appliance. Water conductivity: 50-2000 .S, lower conductivity on request. Maximum chloride concentration (Cl-): below 150 ppm (150 mgr/liter) at any time. For conductivity above 2000 .S or higher chloride concentration use hydrogen-ion exchanger (A in Fig. 15) in the supply water line. Water Redox-Potential must be below 300mV at any time. For higher Redox Potential use Active Carbon Filter (B in Fig. 14). Observe maintenance period of active carbon filter. Use a 3 micron (0.08mm) particle filter (C in Fig. 14) to prevent excessive soiling of the supply water. Recommended test instruments: Cl2 Tester (swimming pool accessories), conductivity tester, redox meter. Optional Treated Water Connection To connect a dual water supply–treated soft water or warm water below 140°F (60°C)–disconnect T-water connection at the two water inlets (Fig. 15). Connect treated water to water inlet marked WZ2 and standard water to inlet marked WZ1. Treated water must comply with the above-mentioned water specifications. NOTE: If using external filter to treat hard water: Contact your Henny Penny distributor for average water consumption when using CleanJet. Increases in average water consumption may exceed specifications of external filters and may affect the frequency of filter maintenance. (See page 57) INSTALLATION General 11) Technical Data Working place specific noise level: <70dB Average water consumption during operation: Model 6: 3.17 gal/hr (0.2 l/min.) Model 10: 6.7 gal/hr (0.42 l/min.) Model 1020: 10.9 gal/hr (.069 l/min.) Model 20: 13.2 gal/hr (0.83 l/min.) Model 40: 15.8 gal/hr (1.0 l/min.) Heat emission: Model Latent Sensible LCS/G-6 .64 W (2.30 kJ)/hr 84 W (2.93 kJ)/hr LCS-G-10 1.05 W (8.50 kJ)/hr 1.4 W (5.00 kJ)/hr LCS/G-1020 1.67 W (6.00 kJ)/hr 2.4 W (8.50 kJ)/hr LCS-G-20 2.13 W (7.67 kJ)/hr 2.67 W (9.60 kJ)/hr LCS/G-40 3.7 W (13.35 kJ)/hr 4.26 W (15.34 kJ)/hr Ventilation Contact your local regulatory agency for ventilation requirements. If a ventilation hood is installed, observe the following: The standards of the local authority. The hood should protrude 12-20 in. (300-500 mm) over the front of the appliance. The integrated grease filter should be in the protruding part of the hood. Specifications and technical descriptions in this applications manual are subject to change without prior notice. Gas supply 12) Gas supply (for LCG units only) The ClimaPlus gas model is available for either natural or propane gas. Check the data plate on the left corner of the unit to determine the proper gas supply requirement. Model Gas Line Connection LCG-6 3.4 in. 1.2 in. LCG-10 3.4 in. 3.4 in. LCG-1020 1 in. 3.4 in. LCG-20 1 in. 3.4 in. LCG-40 11.4 in. 1 in. INSTALLATION continued DO NOT attempt to use any type of gas other than that specified on the data plate. Incorrect gas supply could result in fire or explosion resulting in severe injuries and/or property damage. To avoid possible serious personal injury, the installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1988 or latest edition. In Canada, CAN/CGA-B 149.1 Natural Gas Installation Code CAN/CGA-B 149.2 Propane Installation Code. All Henny Penny Combi-Steamers are equipped with two heat exchanger systems. One is responsible for steam production, the second for dry heat. Each individual heat exchanger is heated with a separate burner assembly. Separate gas valves for the steam burner and dry heat burner are responsible for the gas supply to the individual burners. All LCG models have manual shut-off valves that can be accessed from the left without tools. To operate the valves, un...

Este manual também é adequado para os modelos :
Fornos Elétricos - 6 (227.64 kb)
Fornos Elétricos - 6 (227.64 kb)
Fornos Elétricos - 6 (227.64 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias