•Remove gas cap. Use clean, fresh, regular unleaded gasoline with a minimum of 85 octane. Do not mix oil with gasoline. Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine. • Do not overfill. Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank. To Start Your Generator Never run engine indoors or in enclosed, poor ventilated areas. Engine exhaust contains carbon monoxide, an ordorless and deadly gas. • Move the choke control located on the engine to "CHOKE" position. NOTE: No choke is required on warm engines. Make sure choke is in the "NO CHOKE " position on warm engine starts. "CHOKE " "NO CHOKE " position position CHOKE • Turn the fuel shut-off valve located on the engine to the ON position. Fuel Shut-off valve • Add unleaded gasoline, slowly, to fuel tank. D20346 Rev. 0 2/28/00 12 — ENG • Move ON/OFF switch located on the front panel of • Close fuel shut-off valve. the engine to the "ON" position. Fuel Shut-off Valve ON/OFF Switch NOTE: When engine is transported, close fuel shutoff valve to prevent leakage. You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances. • Grasp handle on rope starter and pull slowly until resistance is felt. Let the rope rewind slowly. Pull rope with a rapid full arm stroke. Let rope rewind slowly. Repeat if necessary. • When engine starts, gradually move the choke to the "NO CHOKE" position. IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine and generator to stabilize. STOPPING ENGINE • Disconnect all electrical loads. • Turn ON/OFF switch to "OFF" position. ON/OFF Switch IMPORTANT: Never store engine with fuel in tank, indoors, or in enclosed, poorly ventilated areas or where fuel fumes may reach an open flame. CONNECTING ELECTRICAL LOADS • Let engine run and warm up for five minutes after starting with no electrical load. Connect loads in the following manner to prevent damage to equipment: • Connect inductive load equipment first, inductive loads consist of refrigerators, freezers, water pumps, air conditioners, or small hand tools. Connect the items that require the most wattage first. • Connect the lights next. • Voltage sensitive equipment should be the last equipment connected to the generator. Plug voltage sensitive appliances such at TV's, VCR's, microwaves, ovens, computers, and cordless telephones into a UL listed voltage surge protector, then connect the UL listed voltage surge protector to the generator. IMPORTANT: You should always add up the rated watts of all lights, tools and appliances you are powering at one time. This total should not exceed the rated capacity of you generator or circuit breaker rating of the receptacle supplying power. D20346 Rev. 0 2/28/00 13 — ENG MAINTENANCE MAINTENANCE CUSTOMER RESPONSIBILITIES TABLE MAINTENANCE TASK Every 8 Hours or Daily Every 25 Hours of Every Season Every 50 Hours of Every Season Every 100 Hours of Every Season Check oil level X Change oil See Note 1 X Service pre-cleaner See Note 2 Service Cartridge X Clean Muffler X Spark Arrester X Clean Cooling System See Note 2 Check Spark Plug X Prepare Unit for Storage Prepare unit for storage if it is to remain idle for more than 30 days. Note 1: Change oil after first five (5) operating hours, every 50 operating hours thereafter, and every 25 hours if operating under heavy load or high ambient temperature, and Note 2: Clean more often under dusty conditions. GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, operator must maintain the generator as instructed in this manual. Some adjustments will need to be made periodically to maintain your generator. GENERATOR MAINTENANCE Your generator should be kept clean and dry at all times. The generator should not be stored or operated in environments that include excessive moisture, dust or any corrosive vapors. If these substances are on the generator, clean with a cloth or soft bristle brush. Do not use a garden hose or anything with water pressure to clean the generator. Water may enter the cooling air slots and could possibly damage the rotor, stator and the internal windings of the generator head. All adjustments in the Maintenance section of this manual should be made at least once each season. ENGINE MAINTENANCE NOTICE: Maintenance, replacement or repair of the emission control devices and systems may be performed by any nonroad engine repair establishment or individual. However, to obtain no charge repairs under the terms and provisions of the engine manufacturers warranty statement, any service or emission control part repair or replacement must be performed by a factory authorized dealer. Oil • ...

Este manual também é adequado para os modelos :
Electricidade - 919.670031 (532.05 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias