Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Bryant, Modelo BRYANT ASPAS1BBA007 ASPAS1BBA012 ASPAS1BBA015

Fabricante : Bryant
Arquivo Tamanho: 723.83 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


26.5 x 12.5 x 7 ....................... 26.5 x 12.5 x 7 Total of Pre-wired Circuits .................................................. 8 ............................................ 10 ...........................................12 No. 15A 120V .......................................................... 5 ............................................ 3 ........................................... 5 No. 20A 120V .......................................................... 1 ............................................ 3 ........................................... 3 No. 15A 240V .......................................................... - ............................................ - ........................................... - No. 20A 240V .......................................................... - ............................................ 1 ........................................... 1 No. 30A 240V .......................................................... 1 ............................................ 1 ........................................... 1 Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts ...................................10,000 .....................................10,000 ......................................10,000 BRYANT, INC. • 7310 WEST MORRIS STREET • INDIANAPOLIS, IN 46231 • Printed in USA 10.05 CATALOG NO. SS-ASPAS07-02 All specifications are subject to change without notice. Mechanical Dimensions (in inches) Current No.of Height Width Depth Rating Poles H1 H2 W1 W2 100 UL Listed 2 26.5 29.25 8.14 12.5 7 W1 W2 H1 H2 Terminal Wire Ranges ATS Rated Amps Switch Terminal Neutral Lug/Stud Ground Lug 100A 2-Pole UL 1 x 1/0-12 1 x 3/8-16 Stud 1 x 2/0-14 Transfer Switch Features • Electrically operated, mechanically-held contacts for fast, positive connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 160 millisecond transfer time. • Dual coil design. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 1 enclosure is standard on the 100 amp switch. Home Standby - 7kW - 12kW - 15kW Home Standb y - 7kW W GENERATOR Model ASPAS1BBA007 (7kW) Model ASPAS1BBA012 (12kW) Model ASPAS1BBA015 (15kW) Rated Maximum Continuous Power Capacity (LP)................................... 7,000 Watts* . . . . . . . . . . . . . . . . . . .12,000 Watts* . . . . . . . . . . . . . . . . . . .15,000 Watts* Rated Maximum Continuous Power Capacity (NG)...................................6,000 Watts* . . . . . . . . . . . . . . . . . . . .12,000 Watts* . . . . . . . . . . . . . . . . . . .13,000 Watts* Rated Voltage................................................................................................. . . . . . . . . . . . . . . . . . . . . . . .120/240 . . . . . . . . . . . . . . . . . . . . . . . .120/240 Rated Maximum Continuous Load Current 120 Volts ................................................................................................ 50.0 NG/58.3 LP . . . . . . . . . . . . . . . 100.0 NG/100.0 LP . . . . . . . . . . . . . . .108.3 NG/125.0 LP 240 Volts ................................................................................................ 25.0 NG/29.2 LP . . . . . . . . . . . . . . . .50.0 NG/ 50.0 LP . . . . . . . . . . . . . . . . .54.2 NG/62.5 LP Main Line Circuit Breaker ............................................................................. 30 Amp . . . . . . . . . . . . . . . . . . . . . . . .50 Amp . . . . . . . . . . . . . . . . . . . . . . . .65 Amp Phase ................................................................................................................ .1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Number of Rotor Poles .......................................................................................2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Rated AC Frequency ........................................................................................60Hz . . . . . . . . . . . . . . . . . . . . . . . . . .60Hz . . . . . . . . . . . . . . . . . . . . . . . . . .60Hz Power Factor .......................................................................................................1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Battery Requirement (not included) ..........................................................Group 26 . . . . . . . . . . . . . . . . . . . . . . . .Group 26 . . . . . . . . . . . . . . . . . . . . . . .Group 26 12 Volts and . . . . . . . . . . . . . . . . . . . .12 Volts and . . . . . . . . . . . . . . . . . . . . .12 Volts and 350 Cold-cranking . . . . . . . . . . . . . . .525 Cold-cranking . . . . . . . . . . . . . . . .525 Cold-cranking Amperes Minimum . . . . . ...

Este manual também é adequado para os modelos :
Electricidade - BRYANT ASPAS1BBA007 (723.83 kb)
Electricidade - BRYANT ASPAS1BBA015 (723.83 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias