Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Generac, Modelo W/K60

Fabricante : Generac
Arquivo Tamanho: 202.82 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


SECTION 4: MAINTENANCE OF YOUR AK STEAM GENERATOR The steam generator, steam head, fittings and plumbing connections should be inspected regularly for water leaks and damage. The AK steam generator is equipped with a manual drain valve for flushing sediments from the generator tank. This procedure should be scheduled monthly or more often depending on local water conditions and steam bath usage. Flushing Procedures: 4. The unit will drain without heating the water. 1. The generator should be cool. 5. Allow the water to run for a full 10 minutes. 2. Press the control ON. 6. Push the control OFF. When the water stops flowing out the drain, close the manual drain 3. Open the manual drain valve. valve. 4209-24 12-09-02 AK Series w/K60 Control Owners Manual page 3 SECTION 5: TROUBLE SHOOTING GUIDE The troubleshooting guide is meant as a general aid only. There are no user serviceable parts in the generator. All repairs should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call: AMEREC's Service Department at 1-800-331-0349. SYMPTOMS PROBABLE CAUSES ACTION TO BE TAKEN Control won't turn "ON". (Control light off). Improper power supplied (no power). or Control improperly connected. or Control cable is faulty. or Contol is faulty. 1. a. Make sure circuit breaker is "ON". b. Using a voltmeter, check the voltage across the two fuses on the "PCA" printed circuit assembly. Voltage should be 208V / 240V. c. Check fuses, if the fuse(s) are blown, replace with Buss# MDL 15/100 or equivalent fuse. If the fuse blows again -call AMEREC's Service Department. 2. Check control(s) instal ll ed per Section 6-5 in the AK INSTALLATION AND SERVICE INSTRUCTIONS. 3. Replace control cable -call AMEREC's Service Department. 4. Replace the control -Call AMEREC's Service Department. Control "OFF". Unit stil ll makes steam. Generator is faulty. 1. Turn off the circuit breaker. 2. Call AMEREC's Service Department. Water runs out of steam head. Generator is faulty. 1. Turn off the circuit breaker. 2. Turn off the water. 3. Call AMEREC's Service Department. Steam room too hot or cold. Temperature adjustment needs setting. 1. See Section 3, "Temperature Adjustment". 2. Call AMEREC's Service Department. Control "ON". K60 Control displays "E001". Temperature sensor not connected. 1. Check that the sensor cable is connected to J4 on the PCA printed circuit assembly. 2. Check the cable connection to the temperature sensor. 3. Replace sensor and/or cable -call AMEREC's Service Department. Control "ON". K60 Control displays "E002". Temperature sensor. or cable shorted. 1. Check sensor cable for damage from nail/staple puncture. 2. Check sensor cable ends for frayed/exposed wire strands. 3. Replace sensor and/or cable -call AMEREC's Service Department. Control "ON". K60 Control displays ">>>.". Steambath temperature over 132 .. or Sensor/cable is faulty. 1. If bath is too hot, shut off circuit breaker and call AMER...

Este manual também é adequado para os modelos :
Electricidade - AK10 (202.82 kb)
Electricidade - AK10 (202.82 kb)
Electricidade - AK5 (202.82 kb)
Electricidade - AK10 (202.82 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias