Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Campbell Hausfeld, Modelo GN0950

Fabricante : Campbell Hausfeld
Arquivo Tamanho: 641.09 kb
Arquivo Nome : 7169c40b-aa77-4d66-b882-811130c6ab66.pdf
Língua de Ensino: enespt
Ir para baixar



Facilidade de uso


Dry with a clean cloth. Reinstall compression cycle, and the intake to closed (horizontal) in generator. and exhaust valves are closed. (The position. Remove fuel piston pushes a small amount of air filter and from the spark plug hole on disassemble. compression). 6. To clean air filter – Remove filter MAINTENANCE SCHEDULE from generator. Wash in a solvent. Pour motor oil (SAE #20) on filter, squeeze out excess and reinstall in generator. Item Action Every 50 hours Every 150 hours or every month or every 3 months Spark Plug Remove carbon Adjust gap Replace if necessary Air Filter Clean Replace if necessary Fuel Filter Clean Replace if necessary Decarbonization Remove carbon deposits Check and adjust at your dealer G/Y G/Y R AC receptacle Engine stop switch Ignition coil 24 . F/250VAC (10.F/300VAC) B 0 0 AC circuit breaker 3A (2A) Stator assembly Rotor assembly MagnetoC.D.I unitSpark plug OFF/ON B B Br G/Y Br 0W/R B = Black R = Red G = Green Br = Brown O = Orange G/Y = Green/Yellow B/W= Black/White G/Y RR AC receptacleAC protector Output light 24 . F/300VAC Stator assembly Rotor assembly Oil annunciator Oil sensor Oil pilot light OFF/ON Engine stop switch T.C.I. unit 10A (6.5A) 1 2 3 4 Br G G B G/Y YB/W B/W 220V 220V Capacitor B = Black R = Red G = Green Br = Brown G/Y = Green/Yellow B/W= Black/White Wiring diagram for GN0800 Wiring diagram for GN0950 4 GN0950 and GN0800 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Zero output from receptacles 1. Engine speed is too slow 2. Open or shorted wiring 1. Adjust engine speed . 2. Clean and reconnect all wiring . 3. Faulty capacitor 4. Open/shorted rotor or stator windings 5. Open rectifier 3. Replace capacitor . 4. Test winding resistance, replace winding if necessary . 5. Test rectifier, replace if necessary . Low output voltage with no load 6 Vac or above 1. Engine speed is too slow 2. Open rectifier 3. Faulty capacitor 4. Open/shorted rotor or stator windings 1. Adjust engine speed . 2. Test rectifier, replace if necessary . 3. Replace capacitor . 4. Test winding resistance, replace winding if necessary . Below 6 Vac 1. Generator head not magnetized 1. Re-magnetize generator head . High output voltage with no load 1. Faulty capacitor 2. Engine speed is too fast 1. Replace capacitor . 2. Adjust engine speed . Low output voltage under load 1. Open rectifier 2. Engine speed too slow at full load 3. Excessive load applied 1. Test rectifier, replace if necessary . 2. Adjust engine speed . 3. Reduce the applied load Erratic output voltage 1. Dirty, corroded, or loose wiring connection 2. Unbalanced load applied 1. Referring to the wiring diagram, clean and reconnect all wiring . 2. Remove all loads, then apply each one individually to determine which one is causing erratic function Noisy operation 1. Loose generator or engine bolt 2. Short circuit in generator field or load 3. Faulty bearing 1. Tighten all mountings 2. Test winding resistance, replace field winding if necessary. Test load devices for shorts. Replace defective load device. 3. Replace bearing Engine won’t start 1. No fuel. 1. Check fuel. Use a 50:1 mix of gas and oil. (See page 2) 2. Fuel switch is in closed position. 2. Place fuel switch in open position. 3. Engine switch is in closed position. 3. Place engine switch in open position. 4. Spark plug dirty or wrong gap 4. Clean spark plug. Adjust gap. (See page 3) Replace if necessary. . These diagnostic and repair procedures should be performed by an authorized service center. 5 Operating Instructions Limited Warranty 1. DURATION: Ninety (90) days from the date of purchase by the original purchaser. Units used for rental, industrial or commercial purposes are warranted for 90 days from date of purchase. 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 803-1436 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld generator. 4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld portable generator supplied or manufactured by Warrantor. 5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects on material and workmanship which occur within the duration of the warranty period. 6. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. C. Any failure that results from an ...

Este manual também é adequado para os modelos :
Electricidade - GN0800 (641.09 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias