Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Campbell Hausfeld, Modelo SN528K

Fabricante : Campbell Hausfeld
Arquivo Tamanho: 2.31 mb
Arquivo Nome : 0ea02fb1-a732-404f-9cc6-96a2c7f137ca.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extended position after being depressed. Do not operate the stapler if the WCE trip mechanism is not operating properly. Personal injury may occur. 1. Disconnect the air supply from the stapler. 2. Remove all staples from the magazine (See Loading- Unloading). ! CAUTION sure the staples are not dirty or damaged. 4. Push the magazine cover forward until the latch catches. 5. Always unload all fasteners before removing tool from service. Unloading is the reverse of loading, except always disconnect the air hose before unloading. ADJUSTING THE STAPLE PENETRATION 1. Regulate the air pressure to 50 psi at the stapler. 2. Connect the air supply and test for penetration by driving staples into a sample piece of wood. If the staples do not achieve the desired penetration, adjust the air pressure to a higher setting until the desired penetration is achieved. Do not exceed 100 psi at the stapler or durability of the stapler will be reduced. CLEARING A JAM FROM THE STAPLER 1. Disconnect the air supply from the stapler. 2. Depress the latch and pull back on the magazine cover. 3. Remove jammed fastener from staple discharge area. 4. Push magazine cover forward until latch catches. 5. Make sure the trigger and Work Contact Element (WCE) move freely up and down without sticking or binding. 3. Make sure the trigger and Work Contact Element (WCE) move freely up and down without sticking or binding. 4. Reconnect air supply to the stapler. 5. Depress the work contact element (WCE) against the work surface without pulling the trigger. The stapler MUST NOT OPERATE. Do not use the stapler if it operates without pulling the trigger. Personal injury may result. 6. Remove the stapler from the work surface. The Work Contact Element (WCE) must return to its original down position. Pull the trigger. The stapler MUST NOT OPERATE. Do not use the stapler if it operates while lifted from the work surface. Personal injury may result. 7. Depress the Work Contact Element (WCE) against the work surface. Pull the trigger. The stapler MUST operate. LOADING/UNLOADING THE STAPLER 1. Always connect the tool to the air supply before loading fasteners. 2. Turn stapler upside down and depress the latch. Pull back on the magazine cover. 3. Insert a stick of Campbell Hausfeld staples or equivalent (see Fastener Section) into the magazine with the crown side down. Make Operating Instructions Model SN258K 4 Latch Latch movement movement O-rings in trigger valve housing are damaged Loose screws in housing Damaged o-rings Damage to bumper Loose screws Damaged gasket Worn bumper Dirt in nose piece Dirt or damage prevent staples or pusher from moving freely in magazine Damaged pusher spring Inadequate air flow to stapler Worn o-ring on piston or lack of lubrication Damaged o-ring on trigger valve Air leaks Cap gasket leaking Operating Instructions Model SN258K Fasteners The following Campbell Hausfeld staples are available at local retail stores. If you need help locating any item, call customer service at 1-800-543-6400. Campbell Hausfeld staples meet or exceed ASTM Standard F1667. Model # Length Wire Crown Staples Staples Diameter Size Point Finish Collation Per Stick Per Box FN158K00 1/2” 18 Gauge 1/4" Chisel Galvanized/Vinyl Coated Adhesive 100 5000 FN168K00 5/8” 18 Gauge 1/4" Chisel Galvanized/Vinyl Coated Adhesive 100 5000 FN208K00 3/4” 18 Gauge 1/4" Chisel Galvanized/Vinyl Coated Adhesive 100 5000 FN258K00 1” 18 Gauge 1/4" Chisel Galvanized/Vinyl Coated Adhesive 100 5000 Interchange Information Staples used in the Campbell Hausfeld SN258K Finishing Stapler will also work in: Senco LN4450, SJS-LR, SKS L11-15, Hitachi N3804A, Duofast BN-1832S, KN-1848, Stan-Tech SDS 18-14, Atro Minor 90/30, 90/32, 90/40, and Porter Cable NS100. Air leaking at trigger valve area. Air leaking between housing and nose. Air leaking between housing and cap. Stapler skips driving staple. Replace o-rings and check operation of Work Contact Element (WCE) Tighten screws Replace o-rings Replace bumper Tighten screws Replace gasket Replace bumper Clean drive channel Clean magazine Replace spring Check fitting, hose, or compressor Replace and lubricate o-rings Replace o-rings Tighten screws and fittings Replace gasket Troubleshooting Guide Stop using stapler immediately if any of the following problems occur. Serious personal injury could occur. Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center. ! WARNING Problem Cause Solution 5 Technical Support Please call our Tool Hotline at 1-800- 543-6400 with any questions regarding the operation or repair of this tool or for additional copies of this manual. Fastener And Replacement Parts Use only genuine Campbell Hausfeld 18 gauge fasteners (or equivalent - see Fastener Interchange ! WARNING Information). Tool performance, safety and durability could ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias